We have fabricated 63-element linear arrays of micromachined thermopile infrared detectors on silicon substrates. Each detector consists of a suspended silicon nitride membrane with 11 thermocouples of sputtered Bi-Te and Bi-Sb-Te films. At room temperature and under vacuum these detectors exhibit response times of 99 ms, zero frequency D* values of 1.4/spl times/ 10/sup 9/ cmHz/sup 1/2//W and responsivity values of 1100 V/W when viewing a 1000 K blackbody source. The only measured source of noise above 20 mHz is Johnson noise from the detector resistance. These results represent the best performance reported to date for an array of thermopile detectors. A test procedure is described that measures many of the relevant electrical, optical, and thermal properties of the detectors without specialized test structures.
机译:我们已经在硅基板上制造了63个元素的微加工热电堆红外探测器线性阵列。每个检测器由一个悬浮的氮化硅膜组成,该膜具有11个溅射Bi-Te和Bi-Sb-Te膜的热电偶。这些检测器在室温和真空下的响应时间为99 ms,零频率D *值为1.4 / spl次/ 10 / sup 9 / cmHz / sup 1/2 // W,观察时的响应度为1100 V / W 1000 K黑体源。唯一测得的高于20 mHz的噪声源是来自检测器电阻的Johnson噪声。这些结果代表了迄今为止报告的一系列热电堆探测器的最佳性能。描述了一种测试程序,该程序无需专门的测试结构即可测量探测器的许多相关电,光和热性能。