首页> 外文期刊>Earthquake Engineering & Structural Dynamics >Seismic tests on reinforced concrete and steel frames retrofitted with dissipative braces
【24h】

Seismic tests on reinforced concrete and steel frames retrofitted with dissipative braces

机译:耗散支撑加固的钢筋混凝土和钢框架的抗震测试

获取原文
获取原文并翻译 | 示例
           

摘要

Seismic tests have been conducted on two 3-storey structures protected with pressurized fluid-viscous spring damper devices. One of the structures was a reinforced concrete frame with clay elements in the slabs, while the other one was a steel frame with steel/concrete composite slabs. The spring dampers were installed through K bracing in between the floors. The tests were performed by means of the pseudodynamic method, which allowed the use of large and full-size specimens, and by implementing a specific compensation strategy for the strain-rate effect at the devices. The test results allowed the verification of the adequacy of the attachment system as well as the comparison of the behaviour of the unprotected buildings with several protected configurations, showing the benefits of the application of the devices and the characteristics of their performance. The response of the protected structures was always safer than that of the unprotected ones mainly due to a significant increase of equivalent damping. The increase in the damping ratio depends on the level of deformation.
机译:已经对两个三层结构进行了抗震测试,这些结构受加压的流体-粘性弹簧阻尼器装置保护。其中一种结构是在楼板中带有粘土元素的钢筋混凝土框架,而另一种结构是带有钢/混凝土复合板的钢框架。弹簧阻尼器通过地板之间的K型支撑安装。测试是通过准动力学方法进行的,该方法允许使用大型和全尺寸的样本,并通过针对设备的应变率效应实施特定的补偿策略。测试结果允许验证附件系统的适当性,以及比较具有几种受保护配置的未受保护建筑物的行为,从而显示出使用该设备的好处及其性能特征。受保护的结构的响应总是比未受保护的结构更安全,这主要是由于等效阻尼的显着增加。阻尼比的增加取决于变形的程度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号