Two-story, three-bay reinforced concrete (RC) frames with and without internal steel frame (ISF) retrofits were tested using continuous pseudo dynamic test method. The ISFs were installed to the middle bay of the RC frame. Test results indicated that ISF retrofit was beneficial in resisting deformation demands without significant damage under simulated ground motions. The ISF shifted the failure mode of the system from a brittle to a ductile mode. The test results were compared with the results of the nonlinear time history analysis. The analysis results were capable of tracing the overall behavior of global response parameters; however, estimations of local demand parameters were less accurate.
机译:使用连续拟动力试验方法对带有和不带有内部钢制框架(ISF)的两层,三层钢筋混凝土(RC)框架进行了测试。 ISF安装在RC框架的中间托架中。测试结果表明,在模拟地面运动下,ISF改型在抵抗变形要求而不会造成重大损坏的情况下是有益的。 ISF将系统的故障模式从脆性模式转变为延性模式。将测试结果与非线性时程分析结果进行比较。分析结果能够追踪全局响应参数的整体行为;但是,本地需求参数的估计不太准确。