Dynamic External Pelvimetry Test in Third Trimester Pregnant Women: Shifting Positions Affect Pelvic Biomechanics and Create More Room in Obstetric Diameters

机译:第三个三个月孕妇动态外置骨盆试验:移位位置影响骨盆生物力学,并在产科直径中创造更多的空间

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Dystocia in labor is still a clinical challenge. The "contracted pelvis" is the absence of pelvic mobility, which leads to fetal-pelvic disproportion, obstructed labor, and operative delivery. Maternal pelvis biomechanics studies by high technological techniques have shown that maternal shifting positions during pregnancy and labor can create more room in the pelvis for safe delivery. The external and internal pelvic diameters are related. The present study aims to evaluate the external obstetric pelvic diameters in shifting positions using a clinical technique suitable for daily practice in every clinical setting: the dynamic external pelvimetry test (DEP test). Seventy pregnant women were recruited, and the obstetric external pelvic diameters were measured, moving the position from kneeling standing to "hands-and-knees" to kneeling squat position. Results showed modification of the pelvic diameters in shifting position: the transverse and longitudinal diameters of Michaelis sacral area, the inter-tuberosities diameter, the bi-trochanters diameter, and the external conjugate widened; the bi-crestal iliac diameter, the bi-spinous iliac diameter, and the base of the Trillat's triangle decreased. The test showed good reproducibility and reliability. Linear correlations were found between diameters and between the range of motion of the diameters. The maternal pelvis is confirmed to modify the diameters changing its tridimensional shape. The pelvic inlet edge's inclination is inferred to be modified, facilitating the fetal descend. The pelvic outlet enlarged the transverse diameter, facilitating birth. The DEP test estimates the pelvic diameters' modification with postural changes, as magnetic resonance (MR) and computational biomechanics studies have demonstrated.
机译:劳动中的陷入困难仍然是一个临床挑战。 “收缩的骨盆”是没有盆腔的迁移率,这导致胎儿 - 盆腔不成比例,阻塞劳动力和手术递送。高科技技术的母骨盆生物力学研究表明,怀孕和劳动期间的母体移位位置可以在骨盆中创造更多的房间以便安全递送。外部和内部骨盆直径有关。本研究旨在使用适合于每种临床环境的日常做法的临床技术评估换档位置的外部产科盆径直径:动态外部骨盆试验(DEP测试)。招募了七十个孕妇,测量了产科外部盆景直径,从跪地上移动到“手膝盖”到跪下位置。结果表明,骨盆直径在换档位置:迈克莱斯骶骨面积的横向和纵向直径,结核间直径,双脱叶器直径,外部缀合物加宽;双嵴髂直径,双棘髂直径和棘塔的三角形的底部降低。该测试显示出良好的再现性和可靠性。在直径和直径的运动范围之间发现线性相关性。确认母体骨盆改变直径改变其三维形状。推断骨盆入口边缘的倾斜度被修改,促进胎儿下降。骨盆出口扩大了横向直径,促进出生。 DEP测试估计盆腔直径随着姿势变化的改变,因为磁共振(MR)和计算生物力学研究已经证明。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号