Intraocular pressure measurements in cattle, sheep, and goats with 2 different types of tonometers

机译:牛,绵羊和山羊的眼压测量有2种不同类型的眼压计

获取原文

摘要

The aim of this study was to investigate normal intraocular pressure (IOP) values of cattle, sheep, and goats with a rebound tonometer [TonoVet (TV)] and an applanation tonometer [Tono-Pen AVIA (TPA)] and to determine correction functions for the 2 devices. A total of 60 healthy cattle, sheep, and goats (20 of each) underwent slit-lamp biomicroscopy. Intraocular pressure (IOP) readings were taken from both eyes with the 2 different tonometers and statistically analyzed. For calibration purposes, the IOP was preset on each instrument at 5 to 60 mmHg using 5 mmHg increments in 10 bovine, 8 ovine, and 6 caprine freshly enucleated eyes. Readings were taken with both tonometers at each interval and compared to the manometrically controlled IOP (Mann-Whitney U-test, P ≤ 0.05; Bland-Altman plot, and regression analysis). The median IOP measurements (min to max) obtained with the TV were 23 mmHg (12 to 40 mmHg), 11 mmHg (7 to 20 mmHg), and 23 mmHg (9 to 37 mmHg) for cattle, sheep, and goats, respectively. Using the TPA, the median IOP measurements were 16 mmHg (8 to 27 mmHg), 10 mmHg (5 to 18 mmHg), and 13 mmHg (4 to 25 mmHg) for cattle, sheep, and goats, respectively. There were statistically significant differences between the readings taken with the TV and the TPA in all species (Wilcoxon-test, P ≤ 0.05). All measurements obtained with the TV and the TPA during the calibration procedure differed statistically significantly from the manometrically controlled IOP measurements (Mann-Whitney U-test, P ≤ 0.05). For both instruments, regression formulas were calculated to correct the measurements. Both tonometers can be used effectively to assess intraocular pressure in ruminants, using the specific regression formulas.
机译:本研究的目的是调查牛,绵羊和山羊的正常眼压(IOP)值与反弹眼压计[Tonovet(电视)]和一个浅色计[Tono-Pen Avia(TPA)]并确定校正功能对于2个设备。共有60个健康的牛,绵羊和山羊(每个)接受狭缝灯生物显微镜检查。用两种不同的眼压计从眼睛中汲取眼压(IOP)读数,并统计分析。为了校准目的,使用10牛牛,8烯烃和6个Caprine的每种仪器在每种仪器上预设5至60mmHg的每种仪器。每个间隔的双胞胎计读数读数,并与机芯控制的IOP(Mann-Whitney U-Test,P≤0.05; Bland-Altman绘图和回归分析)相比。用电视获得的中位IOP测量(MIN至MAX)分别获得23mmHg(12至40 mmHg),11mmHg(7至20mmHg),分别用于牛,绵羊和山羊的23 mmHg(9至37 mmHg) 。使用TPA,中值IOP测量分别为16mmHg(8至27mmHg),10mmHg(5至18mmHg),分别为牛,绵羊和山羊的13mmHg(4至25mmHg)。使用电视和所有物种中的TPA读数之间存在统计学上的差异(Wilcoxon-Test,P≤0.05)。在校准过程中使用电视和TPA获得的所有测量值不同于机芯控制的IOP测量值(Mann-Whitney U-Test,P≤0.05)。对于这两种仪器,计算回归公式以校正测量。两种眼压计可以使用特定的回归公式有效地用于评估反刍动物的眼内压力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号