首页> 外文期刊>RSC Advances >Experimental investigation concerning the effect of mass transfer direction on mean drop size and holdup in a horizontal pulsed plate extraction column
【24h】

Experimental investigation concerning the effect of mass transfer direction on mean drop size and holdup in a horizontal pulsed plate extraction column

机译:关于传质方向对水平脉冲板萃取塔中平均液滴尺寸和滞留率影响的实验研究

获取原文
获取外文期刊封面目录资料

摘要

Vertical extraction columns meet the needs of industrial applications, but when height limitation (especially in indoor applications) is a concern it is required to use horizontal columns. Considering the significant role of mass transfer in the sizing and scale-up of horizontal extraction columns, no analytical and experimental investigations have been conducted in this regard. In the present research, the effect of operating parameters including pulsation intensity and phase flow rates on the mean drop size and the dispersed phase holdup values was investigated in a horizontal pulsed sieve-plate column under both mass transfer directions for the toluene–acetone–water, n-butyl acetate–acetone–water and butanol–acetone–water systems. The results show that holdup decreases first and then increases with an increase of pulsation intensity. Increasing dispersed phase velocity also increases holdup. The mean drop size decreases with an increment of pulsation intensity, whereas flow rates of both phases have little impact. Moreover, it is observed that the presence of mass transfer significantly affects the mean drop size and holdup. Finally, new correlations were proposed for the prediction of mean drop size and holdup based on operating variables and physical properties of the systems with and without mass transfer. Average Absolute Relative Error (AARE) of the correlations was between about 6.83–15.38% for their optimized constants.
机译:立式萃取塔可满足工业应用的需求,但是当需要限制高度(特别是在室内应用中)时,则需要使用卧式塔。考虑到传质在水平萃取塔的尺寸和规模放大中的重要作用,在这方面尚未进行任何分析和实验研究。在本研究中,在甲苯-丙酮-水两个传质方向上,在水平脉冲筛板塔上研究了包括脉动强度和相流速在内的操作参数对平均液滴尺寸和分散相保持值的影响。 ,乙酸正丁酯-丙酮-水和丁醇-丙酮-水系统。结果表明,随着脉动强度的增加,滞留率先降低,然后增加。分散相速度的增加也会增加滞留率。平均液滴尺寸随着脉动强度的增加而减小,而两相的流速几乎没有影响。而且,观察到传质的存在显着影响平均液滴尺寸和保持率。最后,提出了新的相关性,用于基于操作变量和带有或不带有传质的系统的物理特性来预测平均液滴尺寸和保持率。对于它们的优化常数,相关的平均绝对相对误差(AARE)在大约6.83-15.38%之间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号