Monitoring systems are needed to obtain information about particulate matter (PM) concentrations and to make such information accessible to the public. Small, low-cost, optical sensors could be used to improve the spatial and temporal resolution of PM data. The paper presents results of collocated comparison of four low-cost PM sensors and TEOM analyser, conducted from 20-08-2017 to 24-12-2017 in Wroc?aw, Poland. Plantower PMS7003 and Nova Fitness SDS011 sensors proved to be the best in terms of precision and were linearly correlated with TEOM data. Alphasense OPC-N2 sensors exhibited only moderate precision and linearity. Winsen ZH03A sensors had low repeatability between units and only one copy demonstrated good operation possibilities. All tested sensors had a bias in relation to PM_(2.5)concentrations obtained from TEOM.
机译:需要监测系统来获取有关颗粒物(PM)浓度的信息,并使公众可以获取这些信息。小型,低成本的光学传感器可用于改善PM数据的空间和时间分辨率。本文介绍了四种低成本PM传感器和TEOM分析仪的并置比较结果,该结果于2017年8月20日至2017年12月24日在波兰弗罗茨瓦夫进行。播种机PMS7003和Nova Fitness SDS011传感器在精度方面被证明是最好的,并且与TEOM数据线性相关。 Alphasense OPC-N2传感器仅表现出中等的精度和线性度。 Winsen ZH03A传感器之间的重复性很低,只有一个副本显示出良好的操作可能性。所有测试的传感器相对于从TEOM获得的PM_(2.5)浓度都有偏差。