We describe a highly sensitive and specific method for determining L-carnitine in serum by use of carnitine dehydrogenase (EC 1.1.1.108). The method involves a new enzymatic cycling technique with NADH, thio-NAD+, and carnitine dehydrogenase, and measures the increase of absorbance at 415 nm of thio-NADH produced at 37 degrees C during the reaction: [formula: see text] The calibration curve for L-carnitine in serum was linear between 5 and 250 mumol/L. Analytical recovery was 96.5-106%, and within-run and between-run imprecisions (CV) were 0.66-4.33% and 1.02-2.56%, respectively. This method was free from interference by bilirubin, hemoglobin, various acyl-DL-carnitines, and ascorbate. The procedure is simple, rapid, accurate, and automatable. The amount of free L-carnitine in serum (53.6 +/- 11.7 mumol/L, n = 200) was greater in men than in women (45.1 +/- 14.2 mumol/L, n = 200) (mean +/- SD).
机译:我们描述了通过使用肉碱脱氢酶(EC 1.1.1.108)测定血清中左旋肉碱的高度灵敏和特异的方法。该方法涉及使用NADH,thio-NAD +和肉碱脱氢酶的新酶循环技术,并测量反应过程中在37摄氏度下产生的thio-NADH在415 nm处的吸光度增加:[公式:参见文本]校准曲线血清左旋肉碱的线性在5和250μmol/ L之间。分析回收率为96.5-106%,运行中和运行间不精确度(CV)分别为0.66-4.33%和1.02-2.56%。该方法不受胆红素,血红蛋白,各种酰基DL-肉碱和抗坏血酸的干扰。该过程简单,快速,准确且可自动化。男性血清中的游离左旋肉碱含量(53.6 +/- 11.7 mumol / L,n = 200)比女性多(45.1 +/- 14.2 mumol / L,n = 200)(平均值+/- SD )。