Various separation modes in HPLC, such as anion exchange (AE), reversed-phase (RP), and affinity (AF) chromatography were examined for the separation of selenium species in human blood serum and urine. While RP- and AE-HPLC were mainly used for the separation of small molecular selenium species, double column AF-HPLC achieved the separation of selenoproteins in blood serum efficiently. Further, the effluent of AFHPLC was enzymatically hydrolyzed and then analyzed with RP HPLC for selenoamino acid study. The versatility of the hybrid technique makes the in-depth study of selenium species possible. For quantification, post column isotope dilution (ID) with 78Se spike was performed. ORC ICP/MS (octapole reaction cell inductively coupled plasma/mass spectrometry) was used with 4 mL min−1 Hydrogen as reaction gas. In urine sample, inorganic selenium and SeCys were identified. In blood serum, selenoproteins GPx, SelP and SeAlb were detected and quantified. The concentration for GPx, SelP and SeAlb was 22.8 ± 3.4 ng g−1, 45.2 ± 1.7 ng g−1, and 16.1 ± 2.2 ng g−1, respectively when 80Se/78Se was used. The sum of these selenoproteins (84.1 ± 4.4 ng g−1) agrees well with the total selenium concentration measured with the ID method of 87.0 ± 3.0 ng g−1. Enzymatic hydrolysis of each selenium proteins revealed that SeCys is the major amino acid for all three proteins and SeMet is contained in SeAlb only.
机译:检查了HPLC中的各种分离模式,例如阴离子交换(AE),反相(RP)和亲和(AF)色谱法,用于分离人血清和尿液中的硒。 RP-和AE-HPLC主要用于小分子硒的分离,而双柱AF-HPLC可有效分离血清中的硒蛋白。此外,将AFHPLC的流出物进行酶水解,然后用RP HPLC进行硒氨基酸研究。混合技术的多功能性使得对硒物种的深入研究成为可能。为了定量,使用78Se尖峰进行柱后同位素稀释(ID)。使用ORC ICP / MS(八极反应池感应耦合等离子体/质谱)和4 mL min-1氢气作为反应气体。在尿液样本中,鉴定出了无机硒和SeCys。在血清中,检测并定量了硒蛋白GPx,SelP和SeAlb。当使用80Se / 78Se时,GPx,SelP和SeAlb的浓度分别为22.8±3.4 ng g-1、45.2±1.7 ng g-1和16.1±2.2 ng g-1。这些硒蛋白的总和(84.1±4.4 ng g-1)与通过ID方法测得的总硒浓度为87.0±3.0 ng g-1吻合得很好。每个硒蛋白的酶促水解表明,SeCys是所有三种蛋白的主要氨基酸,而SeMet仅包含在SeAlb中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号