首页> 外文期刊>Journal of the Chilean Chemical Society >EVALUATION OF MONOLITHIC COLUMN FOR INORGANIC MERCURY AND METHYLMERCURY DETERMINATION IN FISH SAMPLE ANALYSIS
【24h】

EVALUATION OF MONOLITHIC COLUMN FOR INORGANIC MERCURY AND METHYLMERCURY DETERMINATION IN FISH SAMPLE ANALYSIS

机译:鱼类样品分析中单价柱评估无机汞和甲基汞的测定

获取原文
           

摘要

In the present work, the applicability of a monolithic column was evaluated for mercury speciation analysis in certified and real fish samples. The influence of the flow and composition of the mobile phase (2-mercaptoethanol concentration and methanol content) on the retention times of iHg and MeHg was evaluated. The optimal separation conditions were achieved for a mobile phase containing 5 % methanol and 0.02 % mercaptoethanol in acetate buffer (pH 5.0) at a flow rate of 1.6 ml min−1. Different extraction conditions were studied to analyze a certified reference material with the optimized methodology and the best results (93 % recovery) were obtained for microwave-assisted extraction with a mixture of HCl 6 M + NaCl 0.5 M. Finally, the proposed method was satisfactorily applied to real fish samples collected from different markets in the central region of Chile, presenting levels ranging from 0.73 – 3.4 mg kg−1.
机译:在当前的工作中,评估了整体柱的适用性,以用于认证的和真实的鱼样品中的汞形态分析。评估了流动相的流量和组成(2-巯基乙醇浓度和甲醇含量)对iHg和MeHg保留时间的影响。对于流动相,在乙酸缓冲液(pH 5.0)中包含5%甲醇和0.02%巯基乙醇的流动相,以1.6 ml min-1的流速实现了最佳分离条件。研究了不同的萃取条件,以优化的方法分析了认证的参考物质,并以HCl 6 M + NaCl 0.5 M的混合物进行微波辅助萃取,获得了最佳结果(回收率达93%)。最后,该方法令人满意应用于从智利中部不同市场采集的真实鱼类样品,含量范围为0.73 – 3.4 mg kg-1。