...
首页> 外文期刊>Drugs in R&D >Stability of Etoposide Solutions in Disposable Infusion Devices for Day Hospital Cancer Practices
【24h】

Stability of Etoposide Solutions in Disposable Infusion Devices for Day Hospital Cancer Practices

机译:日间医院癌症实践中一次性输液设备中依托泊苷溶液的稳定性

获取原文
   

获取外文期刊封面封底 >>

       

摘要

In a context of day hospital care of cancer patients, a protocol combining etoposide and carboplatin is used in paediatrics. Disposable infusion devices can be used to improve patient quality of life and to optimize nursing time. Stability data are available for carboplatin in these devices but not for etoposide. The aim of this study was to determine the stability of etoposide solutions in these devices by monitoring the changing etoposide concentration. To study the changing etoposide concentration, we investigated three different concentrations, each in two different solvents: sodium chloride (NaCl) 0.9?% and dextrose 5?%, in Intermate? disposable infusion devices. Quantitative analyses were performed by high-performance liquid chromatography coupled with ultraviolet (UV) detection on samples collected over a 24-h study period. The results showed that 100?mg/L etoposide solutions were stable for 24?h in NaCl 0.9?% and for 12?h in dextrose 5?%, whatever the temperature. The 400-mg/L solutions were stable for 24?h in both diluents, whatever the temperature, whereas the 600-mg/L solutions when diluted in NaCl 0.9?% and dextrose 5?% in water were stable for 8 and 6?h, respectively. We found that precipitation was the main phenomenon responsible for decreased etoposide concentrations. This study allowed us to conclude that etoposide solutions prepared in Intermate? infusion devices are stable for day hospital administration in paediatrics. It will also allow us to conduct a future clinical study that will focus on the medico-economic feasibility of this protocol and on the evaluation of patient and nurse satisfaction.
机译:在癌症患者的日间医院护理的背景下,儿科患者使用结合了依托泊苷和卡铂的方案。一次性输液设备可用于改善患者的生活质量并优化护理时间。这些设备中的卡铂的稳定性数据可用,而依托泊苷则没有。这项研究的目的是通过监测变化的依托泊苷浓度来确定依托泊苷溶液在这些装置中的稳定性。为了研究依托泊苷浓度的变化,我们在Intermate ?一次性输液设备中研究了三种不同的浓度,每种浓度分别在两种不同的溶剂中:氯化钠(NaCl)0.9%和葡萄糖5 %%。通过高效液相色谱结合紫外(UV)检测对24小时研究期间收集的样品进行定量分析。结果表明,无论温度如何,100?mg / L依托泊苷溶液在0.9%NaCl中稳定24?h,在5 %%葡萄糖中稳定12?h。不论温度如何,在两种稀释剂中400 mg / L的溶液均可稳定保持24小时,而在0.9%的NaCl和5%的右旋糖水溶液中稀释时,600 mg / L的溶液对于8和6%的溶液稳定。 h,分别。我们发现沉淀是造成依托泊苷浓度降低的主要现象。这项研究使我们得出结论,在Intermate ?输液设备中制备的依托泊苷溶液对于儿科日间医院管理是稳定的。它还将使我们能够进行未来的临床研究,重点是该方案在药物经济学上的可行性以及对患者和护士满意度的评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号