首页> 外文期刊>Ophthalmology and therapy. >Electron Beam Irradiated Corneal Versus Gamma-Irradiated Scleral Patch Graft Erosion Rates in Glaucoma Drainage Device Surgery
【24h】

Electron Beam Irradiated Corneal Versus Gamma-Irradiated Scleral Patch Graft Erosion Rates in Glaucoma Drainage Device Surgery

机译:青光眼引流设备手术中电子束辐照角膜与伽玛辐照巩膜贴片侵蚀率的关系

获取原文
获取外文期刊封面目录资料

摘要

IntroductionPatch graft erosion and implant exposure is a known complication of glaucoma drainage device (GDD) surgery. Recently, electron beam (e-beam) irradiated corneal tissue ha s become available; however, limited data exist on the rates of erosion for e-beam irradiated corneal grafts compared to traditional scleral grafts after GDD surgery. MethodsThis retrospective study examines the records of 253 eyes from 225 adult subjects who underwent GDD surgery with either e-beam irradiated corneal or scleral grafts at the Casey Eye Institute by five surgeons between April 22, 2014 and October 11, 2017. Surgical procedures and the occurrence of graft erosion were determined using billing codes and verified by manual review of electronic health records. ResultsThe average age at the time of surgery was 61.3?±?17.5?years ( n =?200) and 60.8?±?16.8?years ( n =?53) for the e-beam irradiated cornea and sclera groups, respectively. The average follow-up time post-surgery was 416?±?345?days and 495?±?343?days for the e-beam irradiated cornea and sclera groups, respectively. There were no statistically significant differences in sex, age, follow-up time, and glaucoma diagnosis between the groups; however, the e-beam irradiated cornea group was statistically more likely to have an Ahmed implant as compared to the sclera group. No erosion events were noted in either group. Conclusione-Beam irradiated corneal grafts were used 3.8 times more frequently relative to scleral grafts, yet there were no cases of graft erosion in either group during the follow-up period.
机译:简介修补移植物侵蚀和植入物暴露是青光眼引流装置(GDD)手术的已知并发症。近来,已经有可用电子束(e-束)照射的角膜组织。但是,与GDD手术后的传统巩膜移植相比,电子束辐照的角膜移植物的侵蚀率数据有限。方法这项回顾性研究调查了2014年4月22日至2017年10月11日期间由5位外科医生在Casey眼科研究所进行的用电子束照射角膜或巩膜移植物进行GDD手术的225名成年受试者中253眼的记录。使用计费代码确定移植物侵蚀的发生,并通过人工检查电子健康记录进行验证。结果接受电子束照射的角膜和巩膜组的平均手术年龄分别为61.3±17.5年(n = 200)和60.8±16.8年(n = 53)。电子束照射的角膜和巩膜组的平均术后随访时间分别为416±±345天和495±±343天。两组之间在性别,年龄,随访时间和青光眼诊断方面无统计学差异。然而,与巩膜组相比,经电子束照射的角膜组在统计学上更有可能植入Ahmed植入物。两组均未发现侵蚀事件。结论e-Beam照射的角膜移植物的使用频率是巩膜移植物的3.8倍,但在随访期间,两组均未发生移植物侵蚀的情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号