T组合心肺复苏仪在新生儿复苏中的应用

机译:T组合心肺复苏仪在新生儿复苏中的应用

获取原文
       

摘要

Abstract:Objective To investigate the efficacy of Tpiece combined cardiopulmonary resuscitation in neonatal resuscitation. Methods A total of 158 newborns with neonatal asphyxia were randomly divided into the control group and the observation group, with 79 cases in each group. The control group was treated with conventional cardiopulmonary resuscitation by selfinflating bag, while the observation group was applied with Tpiece combined conventional cardiopulmonary resuscitation. The Apgar score at 1, 5, and 10 minutes after cardiopulmonary resuscitation was observed and arterial blood gas analysis was performed in both groups. The resuscitation success rate and incidence of pulmonary air leak were compared between two groups.  Results The Apgar score at 1, 5, and 10 minutes were higher in the observation group than those in the control group (P<0.05 or P<0.01). There was no significant difference in arterial blood gas analysis between two groups (P>0.05). The observation group had a lower incidence of pulmonary air leak compared with the control group (0.0% vs. 7.6%, P<0.05), and a higher resuscitation success rate compared with the control group (975% vs. 82.3%). Conclusion Tpiece combined cardiopulmonary resuscitation can reduce the risk of pulmonary air leak and improve the efficacy of neonatal resuscitation.
机译:摘要:目的探讨T片联合心肺复苏在新生儿复苏中的疗效。方法将158例新生儿窒息新生儿随机分为对照组和观察组,每组79例。对照组采用自充气袋进行常规心肺复苏术,观察组采用T形件联合常规心肺复苏术。观察两组在心肺复苏后1、5和10分钟的Apgar评分,并进行动脉血气分析。比较两组的复苏成功率和肺漏气的发生率。结果观察组在1、5和10分钟时的Apgar评分高于对照组(P <0.05或P <0.01)。两组之间的动脉血气分析无显着差异(P> 0.05)。观察组与对照组相比,肺气漏发生率较低(0.0%比7.6%,P <0.05),复苏成功率高于对照组(975%与82.3%)。 。结论T形结合心肺复苏可以降低肺漏气的风险,提高新生儿复苏的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号