Lead (Pb) exposure is associated with adverse health effects in both humans and wildlife. Blood lead levels (BLL) of sentinel wildlife species can be used to monitor environmental lead exposure and ecosystem health. BLL analysers, such as the LeadCare?, are validated for use in humans, assessed for use in some avian species and cattle, and are increasingly being used on wildlife to monitor lead exposure. The LeadCare? analysers use a technique called anodic stripping voltammetry (ASV). Species-specific conversion equations have been proposed to approximate the levels found with gold standard measuring methods such as inductively coupled plasma mass spectrometry (ICP-MS) because the ASV method has been shown to underestimate BLL in some species. In this study we assessed the LeadCare? Plus (LCP) for use on Scandinavian brown bears (Ursus arctos). LCP measurements were correlated with ICP-MS with a Bland-Altman analysed bias of 16.3 – 22.5%, showing a consistent overestimation of BLL analysed with LCP. Based on this analysis we provide conversion equations for calculating ICP-MS blood lead levels based on the LCP results in Scandinavian brown bears. Our study shows that the LeadCare? Plus can be used for monitoring of lead exposure by approximating gold standard levels using conversion equations. This enables comparison with other gold standard measured lead levels within the observed range of this study (38.20 – 174.00 μg/L). Our study also found that Scandinavian brown bears are highly exposed to environmental lead.
机译:铅(Pb)暴露对人类和野生生物均具有不利的健康影响。前哨野生动植物物种的血铅水平(BLL)可用于监测环境铅暴露和生态系统健康。 BLL分析仪(例如LeadCare?)经过验证可用于人类,已评估可用于某些禽类和牛,并且越来越多地用于野生生物以监测铅暴露。 LeadCare?分析仪使用一种称为阳极溶出伏安法(ASV)的技术。有人提出了特定物种的转换方程,以近似于金标准测量方法(如电感耦合等离子体质谱法(ICP-MS))中发现的水平,因为已证明ASV方法低估了某些物种的BLL。在这项研究中,我们评估了LeadCare?加号(LCP)用于斯堪的纳维亚棕熊(Ursus arctos)。 LCP测量值与ICP-MS相关联,Bland-Altman分析的偏倚为16.3 – 22.5%,这表明用LCP分析的BLL始终被高估。基于此分析,我们提供了基于斯堪的纳维亚棕熊的LCP结果计算ICP-MS血铅水平的转换方程。我们的研究表明,LeadCare?通过使用转换方程式近似金标准水平,Plus可以用于监测铅暴露。这可以与本研究观察范围内(38.20 – 174.00μg/ L)的其他金标准测得的铅含量进行比较。我们的研究还发现,斯堪的纳维亚棕熊高度暴露于环境铅中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号