Objectives: To identify the frequency of change of chlorhexidine-impregnated gel dressings applied in central venous catheter insertion sites, describe reasons for dressing changes, and identify the amount of dressings used per adult patients admitted to an intensive care unit. Methods: Descriptive study consisting of daily record of occurrence evaluation, reason for dressing change and quantity used per patient, between April and December 2014. Descriptive statistical analysis was used. Results: A total of 159 dressings were applied at the insertion site of 64 central venous catheters whose mean frequency of dressing changes was 3.04 days. The mean number of dressing per patient was 3.1, but 83 unscheduled changes occurred before 7 days of stay, due to detachment, wetness, soiling, and loss of dressing. Conclusion: The frequency of dressing changes was less than seven days, resulting in greater quantities of dressings per patient. Detachment was the most common reason for unscheduled dressing changes.
机译:目的:确定在中央静脉导管插入部位应用氯己定浸渍的凝胶敷料的更换频率,描述敷料变化的原因,并确定每位接受重症监护病房的成年患者使用的敷料数量。方法:描述性研究包括2014年4月至2014年12月之间的发生评估的每日记录,换药原因和每名患者使用的数量。使用描述性统计分析。结果:在64根中心静脉导管的插入部位总共应用了159处敷料,平均敷料更换频率为3.04天。每位患者的平均换药次数为3.1,但在住院7天之前,由于脱落,潮湿,弄脏和换药失败,发生了83次不定期的更换。结论:换药的频率少于7天,导致每位患者换药量增加。分离是不按计划换药的最常见原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号