Following the report of many cases of Legionnaires’ disease associated with accommodation facilities such as hotels, spas, workplaces, hospitals and nursing homes, we verified if Legionella pneumophila and Legionella spp. were present in some of those structures in Tuscany, in order to estimate the species and serogroups in circulation. Legionella pneumophila serogroup 1 (30.9%) was the most frequently isolated species along with serogroups 3 (16.1%) and 6 (13.3%); these three serogroups are identified, in literature, as those most responsible for Legionnaires’ disease (LD). Studying all analyzed structures, we found some parts of the water system where Legionella concentration was higher than 103CFU/L, indicated, in Italy, as the maximum admitted concentration value above which a decontamination treatment is necessary when one or more cases of healthcare-acquired Legionnaires’ disease are observed. Moreover disinfection is recommended in any case when counts exceed 104CFU/L. Consequently, in order to prevent cases of Legionnaires’ disease, a continuous surveillance of the water systems of all accommodation facilities is necessary, with particular attention to hospitals and nursing homes where immunocompromised patients lodge, so as to promptly estimate the presence of the pathogen and consequently plan the most suitable intervention activities. We concluded that, in any structure, a continuous surveillance and disinfecting treatment of water systems is necessary. Moreover, after any disinfection treatment the temperature of the hot water flowing in the system must be necessarily maintained near 51°C in order to minimize the probability of recontamination from Legionella and limit the risk of LD in consumers.
机译:在报告了与住宿设施(如酒店,温泉,工作场所,医院和疗养院)相关的许多退伍军人病病例后,我们验证了肺炎军团菌和军团菌属。存在于托斯卡纳的某些结构中,以估计循环中的物种和血清群。嗜肺军团菌血清群1(30.9%)是最常分离的物种,血清群3(16.1%)和6血清群(13.3%)是最常见的物种。在文献中,这三个血清群被确定为导致退伍军人病(LD)的主要原因。研究了所有已分析的结构,我们发现水系统中军团菌浓度高于103CFU / L的某些部分(在意大利表示)为允许的最大浓度值,如果在一个或多个医疗保健案例中需要进行净化处理,则必须超过该值。观察到军团病。此外,当计数超过104CFU / L时,建议进行消毒。因此,为了预防退伍军人病,必须对所有住宿设施的供水系统进行持续监控,尤其要注意免疫功能低下的患者所在的医院和疗养院,以便及时估计病原体和因此,计划最合适的干预活动。我们得出的结论是,在任何结构中,都必须对水系统进行连续的监视和消毒处理。此外,在进行任何消毒处理之后,必须使系统中流动的热水温度保持在51°C附近,以最大程度地减少军团菌再污染的可能性,并限制消费者遭受LD的风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号