Purpose: Four-dimensional dynamic-ventilation CT imaging demonstrates continuous movement of the lung. The aim of this study was to assess the correlation between interlobar synchrony in lung density and spirometric values in COPD patients and smokers, by measuring the continuous changes in lung density during respiration on the dynamic-ventilation CT. Materials and methods: Thirty-two smokers, including ten with COPD, underwent dynamic-ventilation CT during free breathing. CT data were continuously reconstructed every 0.5 sec. Mean lung density (MLD) of the five lobes (right upper [RU], right middle [RM], right lower [RL], left upper [LU], and left lower [LL]) was continuously measured by commercially available software using a fixed volume of volume of interest which was placed and tracked on a single designated point in each lobe. Concordance between the MLD time curves of six pairs of lung lobes (RU-RL, RU-RM, RM-RL, LU-LL, RU-LU, and RL-LL lobes) was expressed by cross-correlation coefficients. The relationship between these cross-correlation coefficients and the forced expiratory volume in one second/forced vital capacity (FEV1.0/FVC) values was assessed by Spearman rank correlation analysis. Results: In all six pairs of the pulmonary lobes, the cross-correlation coefficients of the two MLD curves were significantly positively correlated with FEV1.0/FVC (ρ =0.60–0.73, P 1.0/FVC (ρ =0.80, P <0.0001). Conclusion: The synchrony of respiratory movements between the pulmonary lobes is limited or lost in patients with more severe airflow limitation.
机译:目的:二维动态换气CT成像可显示肺的连续运动。这项研究的目的是通过在动态通气CT上测量呼吸过程中肺密度的连续变化,评估COPD患者和吸烟者肺间叶间同步性与肺活量值之间的相关性。材料和方法:32名吸烟者,包括10名患有COPD的吸烟者在自由呼吸期间接受了动态换气CT检查。每0.5秒连续重建一次CT数据。五个肺叶(右上[RU],右中[RM],右下[RL],左上[LU]和左下[LL])的平均肺密度(MLD)通过使用固定体积的感兴趣体积,该体积被放置并跟踪在每个瓣的单个指定点上。用互相关系数表示六对肺叶(RU-RL,RU-RM,RM-RL,LU-LL,RU-LU和RL-LL叶)的MLD时间曲线之间的一致性。通过Spearman等级相关分析评估了这些互相关系数与一秒钟的强迫呼气量/强迫肺活量(FEV 1.0 / FVC)之间的关系。结果:在所有六对肺叶中,两条MLD曲线的互相关系数与FEV 1.0 / FVC呈显着正相关(ρ= 0.60–0.73,P 1.0 / FVC(ρ= 0.80,P <0.0001)。结论:气流受限更严重的患者,肺叶之间的呼吸运动同步性受到限制或丧失。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号