首页> 外文期刊>Civil and Environmental Engineering Reports >Design And Construction Problems Connected With Ensuring Even Thermal Insulation Of Single-Layer Walls
【24h】

Design And Construction Problems Connected With Ensuring Even Thermal Insulation Of Single-Layer Walls

机译:与单层墙均匀隔热相关的设计和施工问题

获取原文
       

摘要

The design of single-layer walls appears to be extremely simple. In the opinion of many designers, the additional insulation of tie beams and balconies continues to solve all problems. However, tests on single-layer walls show that the expressed opinion is not valid. The study quotes the results of tests on single-layer walls with strong signs of freezing. The conducted analysis of the design solution and calculation of the fRsi temperature factor on the internal surface and its comparison with fRsi determined empirically enabled reasons behind failure in the construction of the tested walls to be identified. The study presents problems connected with ensuring uniformity of the temperature field in walls, possibilities for detecting areas susceptible to the development of mold, and protection of partitions from the occurrence of this phenomenon by performing appropriate repair works preceding necessary renovations of the building which takes place after the occurrence of mold on walls and ceilings.
机译:单层墙的设计看起来非常简单。在许多设计师看来,附加的横梁和阳台隔热层可以继续解决所有问题。但是,对单层墙的测试表明所表达的观点无效。该研究引用了具有强烈冻结迹象的单层墙的测试结果。对设计解决方案进行了分析,并对内表面上的fRsi温度因子进行了计算,并将其与fRsi进行比较,根据经验确定了能够确定被测墙构造失败的原因。这项研究提出了与确保墙体温度场的均匀性有关的问题,检测易发霉区域的可能性以及通过对建筑物进行必要的装修之前进行适当的维修工作来保护隔板免受这种现象的影响的问题。在墙壁和天花板上发霉之后。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号