1. The VertiScan System proved effective in identifying general wall loss and local thinning. Thinning was confirmed by ultrasonic thickness readings. Thermal Fatigue cracking was confirmed visually and MPI inspections. 2. The scaffold gap must be a minimum of 10" from the crown of the tubes for the VertiScan system to pass by 3. The VertiScan System provides best value when there is no scaffold in the boiler. Generally one full water wall can be scanned per shift if just one system is in use.
机译:1.事实证明,VertiScan系统可有效识别总体壁损和局部变薄。通过超声厚度读数确认变薄。目视和MPI检查确认了热疲劳裂纹。 2.支架间隙必须与管的顶部至少相距10英寸,以使VertiScan系统能够通过。3.如果锅炉中没有支架,VertiScan系统可提供最佳价值。通常可以扫描一个满水的墙如果仅使用一个系统,则每班次。