Tests were made under a contract with VEDA Inc. of Alexandria, Virginia, for the United States Navy, Environmental Protection Branch, Annapolis, Maryland. The objectives of the tests were to demonstrate the use of vapor compression distillation to greatly reduce the storage volume of wastewater on US Navy ships during extended missions, examine the quality of the produced distilled water for reuse, and determine energy requirements for the process. Three 55 gal drums of gray wastewater, shipped from Annapolis, were used in the tests at The Water Reuse Technology (WRT) test facility, Alamo, California. The tests were made in a 3 gal/h vapor compression distillation unit using the energy efficient wiped film rotating disk (WFRD) evaporator. Data were collected to determine recovery, evaporator performance, and distilled water and blowdown qualities. The tests were run at an average temperature of 122℉ in the evaporator. The results show that recoveries as high as 98.6% are possible. Measured energy consumption by the compressor and rotor (for this small unit) varied from 75 to 90 Wh/gal. Samples of the wastewater, distilled water, and blowdown were collected for analysis. The results of the analysis of the distilled water samples indicate that total suspended solids, fecal coliform, and biological oxygen demand were below the detection limits of the instruments used in the analysis. The chemical oxygen demand varied from below 10 mg/L (detection limit) to 30 mg/L.
机译:根据与弗吉尼亚州亚历山大港的VEDA Inc.签订的合同,对美国海军马里兰州安纳波利斯的环境保护局进行了测试。测试的目的是演示在延长任务期间使用蒸汽压缩蒸馏可大大减少废水在美国海军舰船上的存储量,检查所产生的蒸馏水的质量以进行再利用,并确定该过程的能源需求。从安纳波利斯市运来的三个55加仑桶的灰色废水用于加利福尼亚州阿拉莫市的水回用技术(WRT)测试设施的测试中。使用节能刮水膜旋转盘(WFRD)蒸发器在3 gal / h蒸气压缩蒸馏单元中进行测试。收集数据以确定回收率,蒸发器性能以及蒸馏水和排污质量。测试在蒸发器中的平均温度为122℉下进行。结果表明,回收率高达98.6%。压缩机和转子(对于这种小型设备)测得的能耗为75至90 Wh / gal。收集废水,蒸馏水和排污样品进行分析。蒸馏水样品的分析结果表明,总悬浮固体,粪大肠菌群和生物需氧量低于分析所用仪器的检测极限。化学需氧量从低于10 mg / L(检测极限)到30 mg / L不等。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号