首页> 外文期刊>Dental materials >The influence of cyclic shear fatigue on the bracket-adhesive-enamel complex: An in vitro study
【24h】

The influence of cyclic shear fatigue on the bracket-adhesive-enamel complex: An in vitro study

机译:循环剪切疲劳对托槽-胶粘剂-牙釉质复合物的影响:体外研究

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives. To describe the effect of fatigue on the strength of the bracket-adhesive-enamel complex and characterize the fatigue behavior of the materials tested. Methods. Upper central incisor brackets (Discovery®, Dentaurum) were bonded with a light-curing (Transbond XT™, 3M Unitek) and a chemically-curing adhesive (Concise™, 3M Unitek) on bovine teeth embedded in cylindrical resign bases and stored in water at 37(±2) °C for 24 (±2) h. The first IB specimens were tested with a universal testing machine ZMART.PRO~® (Zwick GmbH & Co. KG, Ulm, Germany) for ultimate shear bond strength according to the DIN-13990-2-standard. The remaining three groups of 20 specimens underwent fatigue staircase testing of 100, 1000 and 3000 cycles at 1 Hz with a self-made testing machine. The survived specimens were subjected to shear strength testing. Results. The fatigued specimens showed decreased shear strength with both adhesives at all cycle levels. The shear strength after fatigue for 100, 1000 and 3000 cycles was in the Concise™-groups 34.8%, 59.0%, 47.3% and in the Transbond™ XT-groups 33.6%, 23.1%, 27.3% relative to the ultimate shear strength. The fatigue life of the Concise™-groups decreased with increasing stress and Transbond™ XT showed lower fatigue ratio with no obvious trend. The specimens bonded with Transbond™ XT showed typically favorable fracture modes in contrary to Concise™. Significance. Fatigue of the bracket-adhesive-enamel complex decreased its shear strength. The staircase method can provide a standardized experimental protocol for fatigue studies, however testing at various cycle numbers is recommended.
机译:目标。描述疲劳对托槽-胶粘剂-搪瓷复合材料强度的影响,并表征测试材料的疲劳行为。方法。上部中央门牙托槽(Discovery®,Dentaurum)用光固化(Transbond XT™,3M Unitek)和化学固化胶粘剂(Concise™,3M Unitek)粘结在埋入圆柱状基托中的牛牙上并储存在水中在37(±2)°C下放置24(±2)h。首先使用通用测试机ZMART.PRO〜(Zwick GmbH&Co. KG,德国乌尔姆,德国)测试了IB样品的极限剪切粘结强度,并根据DIN-13990-2-标准进行了测试。剩下的三组20个样品用自制的测试机在1 Hz下进行了100、1000和3000个循环的疲劳阶梯测试。将幸存的样品进行抗剪强度测试。结果。疲劳的样品在所有循环水平下均显示出两种粘合剂的剪切强度降低。相对于极限剪切强度,在100、1000和3000次循环疲劳后的剪切强度在Concise™组中分别为34.8%,59.0%,47.3%,在Transbond™XT组中为33.6%,23.1%,27.3%。 Concise™-组的疲劳寿命随着应力的增加而降低,Transbond™XT的疲劳率更低,没有明显的趋势。与Concise™相反,用Transbond™XT粘结的样品通常表现出良好的断裂模式。意义。托槽-粘合剂-搪瓷复合物的疲劳降低了其剪切强度。阶梯法可以为疲劳研究提供标准化的实验方案,但是建议在各种循环次数下进行测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号