In this work, an outlet temperature control scheme for double-pipe heat exchangers is proposed. Compared to previously proposed approaches, the algorithm developed here takes into account and actually exploits the analytical and stability properties inherent to the open-loop dynamics. As a result, outlet temperature regulation is achieved through a simple controller which does not need to feed back the whole state vector and does not depend on the exact value of the process parameters. Moreover, the proposed approach guarantees positivity and boundedness of the input flow rate without entailing a complex control algorithm. The analytical developments are corroborated through simulation and experimental results.
机译:在这项工作中,提出了一种用于双管热交换器的出口温度控制方案。与以前提出的方法相比,此处开发的算法考虑并实际利用了开环动力学固有的分析和稳定性属性。结果,通过简单的控制器即可实现出口温度调节,该控制器不需要反馈整个状态向量,并且无需依赖于过程参数的确切值。而且,所提出的方法保证了输入流量的正性和有界性,而无需复杂的控制算法。通过仿真和实验结果证实了分析的发展。