首页> 外文期刊>Control Engineering Practice >Active noise control in a forced-air cooling system
【24h】

Active noise control in a forced-air cooling system

机译:强制风冷系统中的主动噪声控制

获取原文
获取原文并翻译 | 示例
       

摘要

This paper discusses the design methodology for the active noise control of sound disturbances in a forced-air cooling system. The active sound cancellation algorithm uses the framework of output-error based optimization of a linearly parametrized filter for feedforward sound compensation to select microphone location and demonstrate the effectiveness of active noise cancellation in a small portable data projector. Successful implementation of the feedforward based active noise controller on a NEC LT170 data projector shows a 20-40 dB reduction per frequency point in the spectrum of external noise of the forced-air cooling system can be obtained over a broad frequency range from 1 to 5 kHz. A total noise reduction (unweighted) of 9.3 dB is achieved.
机译:本文讨论了强制空气冷却系统中噪声干扰的主动噪声控制的设计方法。有源声音消除算法使用基于输出误差的线性参数化滤波器优化框架进行前馈声音补偿,以选择麦克风位置并展示小型便携式数据投影仪中有源噪声消除的有效性。在NEC LT170数据投影仪上成功实施基于前馈的有源噪声控制器,表明在从1到5的宽频率范围内,强制空气冷却系统的外部噪声频谱中的每个频率点降低了20-40 dB千赫。达到了9.3 dB的总降噪(未加权)。