Repairing thin travertine stone panels on a 30-year-old, 22-story building, while minimizing the possible negative aesthetic impact, presents many different challenges for design professionals. This article describes the repairs performed on the travertine exterior wall panels of the Capital One Plaza building located in Houston, Texas. The panels on this building presented distresses such as cracking and spalling. A comprehensive evaluation consisting of field observations, laboratory testing, and structural calculations was performed to understand the condition of the panels, design repairs, and to create a stone selection criteria required to maintain the building's original appearance. Custom-made mortar mix was designed and implemented to parge the exterior of the building and provides the owner the desired monolithic appearance to the travertine panels. Innovative panel connections and repairs were designed and constructed in order to provide supplemental support to the travertine panels.
机译:修复一栋有30年历史的22层建筑物的石灰华薄板,同时最大程度地减少可能的负面美学影响,这对设计专业人员提出了许多不同的挑战。本文介绍了位于德克萨斯州休斯敦的Capital One Plaza大楼的钙华外墙面板所进行的维修。该建筑物上的面板呈现出诸如破裂和剥落之类的困扰。进行了包括实地观察,实验室测试和结构计算在内的综合评估,以了解面板的状况,设计维修以及创建维持建筑物原始外观所需的石材选择标准。设计和实施了定制的砂浆混合物,以凝结建筑物的外部,并为所有者提供了所需的钙华板整体外观。设计和构造了创新的面板连接和维修方法,以便为石灰华面板提供补充支持。