The effects of silica fume ratio and chloride concentration on reinforcement corrosion and crack time of concrete are investigated by accelerated corrosion test. In order to represent the situation that free chloride ions are present in the concrete ingredients in a reinforced concrete structure, solutions having various concentrations of Cl~- ions are used as mix water and 10 cm in diameter 20 cm in height cylindrical reinforced concrete samples are produced. During the accelerated corrosion test, the change of current density over time was recorded and the crack time of concrete was determined. After the test, the weight loss in the rebar and the free Cl~- amount in concrete around the rebar were determined. By using the test results, an equation for predicting the time to crack initiation of a structure because of corrosion damage is developed according to silica fume ratio, free Cl~- concentration and accelerating factor.
机译:通过加速腐蚀试验研究了硅灰比和氯化物浓度对钢筋锈蚀和混凝土开裂时间的影响。为了表示钢筋混凝土结构中混凝土成分中存在游离氯离子的情况,将具有各种浓度的Cl-离子的溶液用作混合水,并使用直径10厘米,高度20厘米的圆柱形钢筋混凝土样品作为混合水。生产的。在加速腐蚀试验中,记录电流密度随时间的变化,并确定混凝土的破裂时间。试验后,确定钢筋的重量损失和钢筋周围混凝土中的游离Cl-含量。通过使用测试结果,根据硅灰比,游离Cl〜-浓度和加速因子,建立了一个预测因腐蚀破坏而导致结构开裂的时间的方程。