This paper presents the results of a study of the effectiveness of lightweight conductive cementitious mortar as an anode material for impressed current cathodic protection of concrete structures. The anode is made up of pumice aggregate (fine), carbon fibres and cement with MMO-Ti as a primary anode. Accelerated galvanic test, conductivity measurement, dry density and compressive strength were carried out and compared with the cement mortar without fibres. Results have shown that the mortar at 20-30% replacement level of pumice aggregate with 1.1% carbon fibre content is a percolation threshold at which highest conductivity of 0.2 S/cm is achieved. The weight of the anode was found to have reduced to half of the weight of the conventional anodes. Polarisation and impedance studies confirmed the possible use of this material as an anode in cathodic protection of reinforced concrete structures.
机译:本文介绍了轻质导电水泥砂浆作为阳极材料对混凝土结构施加外加电流阴极保护的有效性的研究结果。阳极由浮石骨料(细粉),碳纤维和水泥组成,其中MMO-Ti为主要阳极。进行了加速电化试验,电导率测量,干密度和抗压强度,并与不含纤维的水泥砂浆进行了比较。结果表明,灰泥在20%至30%的浮石骨料中具有1.1%的碳纤维含量时,是达到0.2 S / cm的最高电导率的渗流阈值。发现阳极的重量已减少到常规阳极的一半。极化和阻抗研究证实,这种材料可以用作增强混凝土结构阴极保护的阳极。