The suitability of precast concrete walls containing recycled aggregates as the enclosure system of steel structure was investigated. The experiment on steel frame with external hanging concrete walls containing recycled aggregates (SFECW) was carried out under horizontal low-cyclic loading, and the influence of beam-column joints forms on the SFECW was considered. The failure modes, structural capacity, lateral stiffness, ductility and energy dissipation capacity were analyzed. The experimental results show that the external walls can remarkably increase the structural capacity, stiffness and energy dissipation capacity, and the connecting stiffness of beam-column joints has negligible effect. There were obvious buckling deformation of the steel column base and serious cracking and damage of the wall at the hanging points, and the corresponding suggested improvements were proposed. Furthermore, the load-displacement curves and failure modes of the SFECW were investigated by the finite element method, and the influence of key parameters such as the position of hanging points, the strength grade of recycled concrete, the thickness of wall, the height-span ratio and axial compression ratio on the SFECW were discussed. The FEA results indicate that the design parameters associated with the external wall are less affected to hysteresis performance of the SFECW, which provides scientific basis for the design and practical application of the SFECW. (C) 2017 Elsevier Ltd. All rights reserved.
机译:研究了含有再生骨料的预制混凝土墙作为钢结构围护系统的适用性。在水平低周向荷载下,对带有再生骨料的外悬混凝土墙的钢框架进行了试验,并考虑了梁柱接头形式对SFECW的影响。分析了破坏模式,结构能力,侧向刚度,延性和能量耗散能力。实验结果表明,外墙可以显着提高结构能力,刚度和耗能能力,而梁柱节点的连接刚度影响可忽略不计。钢柱基部存在明显的屈曲变形,悬点处墙体严重开裂和损坏,并提出了相应的改进建议。此外,通过有限元方法研究了SFECW的荷载-位移曲线和破坏模式,并研究了关键参数的影响,例如吊点的位置,再生混凝土的强度等级,墙的厚度,墙的高度。讨论了SFECW的跨度比和轴向压缩比。 FEA结果表明,与外墙相关的设计参数对SFECW的滞后性能的影响较小,这为SFECW的设计和实际应用提供了科学依据。 (C)2017 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Construction and Building Materials》 |2017年第30期|790-808|共19页
  • 作者单位

    Xian Univ Technol, State Key Lab Base Ecohydraul Engn Arid Area, 5 Jinhua Rd, Xian 710048, Shaanxi, Peoples R China|Xian Univ Technol, Sch Civil Engn & Architecture, 5 Jinhua Rd, Xian 710048, Shaanxi, Peoples R China;

    Xian Univ Technol, State Key Lab Base Ecohydraul Engn Arid Area, 5 Jinhua Rd, Xian 710048, Shaanxi, Peoples R China|Xian Univ Technol, Sch Civil Engn & Architecture, 5 Jinhua Rd, Xian 710048, Shaanxi, Peoples R China;

    Xian Univ Technol, State Key Lab Base Ecohydraul Engn Arid Area, 5 Jinhua Rd, Xian 710048, Shaanxi, Peoples R China|Xian Univ Technol, Inst Water Resources & Hydroelect Engn, 5 Jinhua Rd, Xian 710048, Shaanxi, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Steel frame; Recycled concrete; External wall; Semi-rigid connection; Failure modes;

    机译:钢框架;再生混凝土;外墙;半刚性连接;失效模式;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号