首页> 外文期刊>Construction and Building Materials >Alternative small-scale tests to characterize the structural behaviour of steel fibre-reinforced sprayed concrete
【24h】

Alternative small-scale tests to characterize the structural behaviour of steel fibre-reinforced sprayed concrete

机译:替代的小规模试验表征钢纤维增强喷涂混凝土的结构行为

获取原文
获取原文并翻译 | 示例

摘要

The flexural beam test EN 14488-3 is considered a reference for the characterization of the post-cracking tensile response of fibre-reinforced sprayed concrete (FRSC). However, the geometry of the specimens is a complication in case of characterising specimens extracted from the structure. The double punch test (DPT) and double-edge wedge splitting (DEWS) test are two alternative approaches that have been introduced to simplify the assessment of the post-cracking response of fibre-reinforced concrete. These tests could allow the characterisation of samples extracted from sprayed test panels or even existing structures. The objective of this experimental study is to demonstrate the possibility to correlate the flexural beam test EN 14488-3, the DPT and DEWS tests, and verify the capacity of these tests in predicting the constitutive model of FRSC. The results indicated high correlations (R-2 above 0.98) between tests. The constitutive models obtained from the alternative tests were close to those determined employing the flexural beam test. Both the DPT and DEWS test can replace the EN 14488-3 test in systematic quality control or for the confirmation of design parameters of FRSC structure. However, the DEWS test requires more time to prepare the specimens, being more appropriate to parameterize the constitutive models of the FRSC. The DPT, due to its simplicity of execution, becomes more practical for quality control of FRSC. Specimen with different size subjected to the DPT show a similar residual strength pattern. (C) 2021 Elsevier Ltd. All rights reserved.
机译:弯曲梁测试EN 14488-3被认为是纤维增强喷涂混凝土(FRSC)的开裂抗拉响应的表征的参考。然而,在表征从结构中提取的样本的情况下,样本的几何形状是一种并发症。双冲击试验(DPT)和双边缘楔形分裂(露水)测试是已经引入的两种替代方法,以简化纤维增强混凝土后开裂响应的评估。这些测试可以允许从喷涂的测试面板或甚至现有结构中提取的样品的表征。该实验研究的目的是证明了与弯曲梁测试,DPT和露水测试相关的可能性,并验证了这些测试在预测FRSC的本构模型方面的能力。结果表明测试之间的高相关(R-2以上0.98)。从替代测试获得的本结构型模型接近采用弯曲梁测试的那些。 DPT和DEWS测试都可以在系统质量控制中取代EN 14488-3测试或用于确认FRSC结构的设计参数。然而,露水测试需要更多时间来准备样品,更适合于参数化FRSC的本构模型。由于其简单性,DPT对FRSC的质量控制变得更加实用。具有不同尺寸的标本对DPT进行了类似的残余强度模式。 (c)2021 elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号