Two blast tests were conducted to study the blast resistance of high performance geopolymer composite walls reinforced with steel wire mesh (SWM) and aluminium foam (AF). Conventional reinforced concrete (CRC) walls were also tested as control specimens. In total seven walls were tested under different blast loading conditions. The first blast test was conducted on one 2260 mm x 2260 mm x 150 mm SWM reinforced, one 2260 mm x 1000 mm x 150 mm SWM reinforced and one 2260 mm x 1000 mm x 150 mm combined SWM and AF reinforced high performance geopolymer composite walls under 50 kg TNT explosives at a standoff distance of 2.3 m. The second blast test was conducted on one 2260 mm x 2260 mm x 150 mm SWM reinforced and one 2260 mm x 2260 mm x 150 mm combined SWM and AF reinforced high performance geopolymer composite walls under 100 kg TNT explosives on the ground at the same standoff distance. Blast tests were also performed on two 2260 mm x 2260 mm x 150 mm CRC walls under such two designed explosions to compare their behaviours with reinforced high performance geopolymer composite walls. LVDT (linear variable differential transformer) devices were used to record the deflection histories and pressure sensors were used to measure the airblast pressure histories. The testing results indicated that the combined SWM and AF reinforced high performance geopolymer composite walls had a better blast resistance than the CRC walls, and the SWM reinforced high performance geopolymer composite wall was superior to both. (C) 2018 Elsevier Ltd. All rights reserved.
机译:进行了两次爆炸测试,以研究用钢丝网(SWM)和泡沫铝(AF)增强的高性能地质聚合物复合墙的爆炸性能。常规钢筋混凝土(CRC)墙也作为对照样品进行了测试。在不同的爆炸载荷条件下,总共测试了七面墙。第一次爆炸测试是在一个2260 mm x 2260 mm x 150 mm SWM增强,一个2260 mm x 1000 mm x 150 mm SWM增强以及一个2260 mm x 1000 mm x 150 mm组合的SWM和AF增强高性能地质聚合物复合墙上进行的50公斤以下的TNT炸药,对峙距离为2.3 m。第二次爆炸测试是在100公斤TNT炸药在同一支距下,对一枚2260 mm x 2260 mm x 150 mm SWM增强型和一枚2260 mm x 2260 mm x 150 mm结合的SWM和AF增强高性能地聚合物复合墙进行的距离。在这两次设计爆炸下,还对两个2260 mm x 2260 mm x 150 mm CRC墙进行了爆炸测试,以比较它们与增强型高性能地质聚合物复合墙的性能。 LVDT(线性可变差动变压器)设备用于记录偏转历史,压力传感器用于测量大风压力历史。测试结果表明,组合的SWM和AF增强高性能地质聚合物复合墙比CRC墙具有更好的抗爆炸性,而SWM增强高性能地质聚合物复合墙则优于两者。 (C)2018 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号