首页> 外文期刊>Computers & Structures >Lateral-torsional buckling of unrestrained steel beams under fire conditions: improvement of EC3 proposal
【24h】

Lateral-torsional buckling of unrestrained steel beams under fire conditions: improvement of EC3 proposal

机译:火灾条件下无约束钢梁的横向扭转屈曲:EC3提案的改进

获取原文
获取原文并翻译 | 示例

摘要

The final draft of the EN version of part 1.1 of Eurocode 3 has introduced significant changes in the evaluation of the lateral-torsional buckling resistance of unrestrained beams at room temperature that reduce the over-conservative approach of ENV 1993-1-1 in the case of non-uniform bending. Numerical modelling of the lateral-torsional buckling of steel beams at elevated temperature has shown that the beam design curve from prEN 1993-1-2 is over-conservative for loadings other than uniform bending. In line with the safety format of the lateral-torsional buckling code provisions for cold design, an alternative proposal for rolled sections or equivalent welded sections subjected to fire is presented in this paper, that addresses the issue of the influence of the loading type on the resistance of the beam, achieving better agreement with the real behaviour while maintaining safety.
机译:欧洲规范3第1.1部分的EN版本的最终草案在评估室温下无约束梁的横向扭转屈曲阻力时引入了重大变化,从而减少了ENV 1993-1-1的过度保守方法弯曲不均匀高温下钢梁横向扭转屈曲的数值模型表明,prEN 1993-1-2中的钢梁设计曲线对于载荷(而不是均匀弯曲)过于保守。根据冷弯设计中横向扭转屈曲规范的安全格式,本文提出了一种用于遭受火灾的轧制型材或等效焊接型材的替代方案,该方案解决了载荷类型对结构的影响。光束的抵抗力,在保持安全性的同时与真实行为更好地达成了一致。