首页> 外文期刊>Computers & Structures >Ultimate strength analysis of prestressed reinforced concrete sections under axial force and biaxial bending
【24h】

Ultimate strength analysis of prestressed reinforced concrete sections under axial force and biaxial bending

机译:轴向力和双轴弯曲作用下预应力钢筋混凝土截面的极限强度分析

获取原文
获取原文并翻译 | 示例

摘要

A secant approach is illustrated for the ultimate limit state (ULS) analysis of prestressed reinforced concrete sections subjected to axial load and biaxial bending in presence of softening stress-strain laws. The stiffness matrix and the resultant loads are evaluated analytically by a novel methodology, termed fiber-free, which represents a computationally efficient alternative to fiber approaches. Extensive computations of the ULS domains of benchmark test cases show that the robustness of the proposed algorithmic strategy is substantially unaffected by the amount of reinforcement, prestressing and softening, though localized non-convex regions have been occasionally experienced in presence of softening.
机译:说明了一种割线方法,用于在存在软化应力应变规律的情况下,对承受轴向载荷和双轴弯曲的预应力钢筋混凝土截面进行极限极限状态(ULS)分析。刚度矩阵和所产生的载荷通过一种称为无纤维的新型方法进行了分析评估,该方法是纤维方法的一种计算有效替代方案。基准测试用例的ULS域的大量计算表明,尽管偶尔会在存在软化的情况下遇到局部非凸区域,但是所提出算法策略的鲁棒性基本上不受增强,预应力和软化量的影响。