首页> 外文期刊>Computer networks >To schedule or not to schedule: When no-scheduling can beat the best-known flow scheduling algorithm in datacenter networks
【24h】

To schedule or not to schedule: When no-scheduling can beat the best-known flow scheduling algorithm in datacenter networks

机译:计划或不计划:当无计划可以击败数据中心网络中最著名的流计划算法时

获取原文
获取原文并翻译 | 示例
       

摘要

Conventional wisdom for minimizing the average flow completion time (AFCT) in the datacenter network (DCN), where flow sizes are highly variable, would suggest scheduling every individual flow. However, we show that considering scheduling delay (including schedulers computational and communication delays), serving most of the flows without any scheduling and only in first-come-first-served (FCFS) manner significantly improves their performance even when it is compared to the shortest remaining processing time (SRPT) known as optimum algorithm when scheduling delay is zero. To do so, we only require to have two coarse classes of flows categorized based on flows sizes (1st-class including flows smaller than a threshold, H, and 2nd-class including others) and serve 1st-class flows always before serving 2nd-class ones. To show that, we take SRPT scheduling algorithm accompanied by the global knowledge of flows, formulate impact of scheduling delay on its performance, and prove that for any flow size distribution and network load (< 1), there is always a threshold, H, which guarantees 1st-class flows achieve lower AFCT under FCFS compared to SRPT. Our numerically calculated results and extensive flow-level simulations show that on average, more than 90% of flows could be in 1st-class and consequently do not require any scheduling.
机译:在流量大小高度可变的数据中心网络(DCN)中,最小化平均流完成时间(AFCT)的传统观点认为,建议对每个单独的流进行调度。但是,我们表明,考虑到调度延迟(包括调度程序的计算和通信延迟),即使不与调度程序进行比较,仅以先到先服务(FCFS)的方式为大多数流提供服务,而无需进行任何调度,就可以显着提高其性能。最短的剩余处理时间(SRPT),即调度延迟为零时的最佳算法。为此,我们仅需要根据流量大小将流量分为两大类(第一类流量包括小于阈值的流量,H,第二类流量包括其他流量),并且始终在为第二类流量提供服务之前为第一类流量提供服务班级的。为了证明这一点,我们将SRPT调度算法与流的全局知识一起使用,阐述了调度延迟对其性能的影响,并证明对于任何流大小分布和网络负载(<1),总会有阈值H,与SRPT相比,这保证了第一类流量在FCFS下达到较低的AFCT。我们的数值计算结果和广泛的流量水平模拟表明,平均而言,超过90%的流量可能属于第一类,因此不需要任何调度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号