首页> 外文期刊>Computer methods in biomechanics and biomedical engineering >Biomechanical comparison of implant inclinations and load times with the all-on-4 treatment concept: a three-dimensional finite element analysis
【24h】

Biomechanical comparison of implant inclinations and load times with the all-on-4 treatment concept: a three-dimensional finite element analysis

机译:采用全4式治疗概念的种植体倾角和负载时间的生物力学比较:三维有限元分析

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to compare the effects of implant inclinations and load times on stress distributions in the peri-implant bone based on immediate- and delayed-loading models. Four 3D FEA models with different inclination angle of the posterior implants (0 degrees, 15 degrees, 30 degrees, 45 degrees) were constructed. A static load of 150 N in the multivectoral direction was applied unilaterally to the cantilever region. The stress distributions in the peri-implant bone were evaluated before and after osseointegration. The principal tensile stress (sigma(max)), mean principal tensile stress (sigma(max)), principal compressive stress (sigma(min)) and mean principal compressive stress (sigma(min)) of the bone and micromotion at the contact interface between the bone and implants were calculated. In all the models, peak principal stresses occurred in the bone surrounding the left tilted implant. The highest sigma(max) and sigma(min) were all observed in the 0 degrees model for both immediate- and delayed-loading models. And the 0 degrees and 15 degrees models showed higher sigma(max) and sigma(min) values. The 0 degrees models showed the largest micromotion. The observed stress distribution was better in the 30 degrees and 45 degrees models than in the 0 degrees and 15 degrees models.
机译:这项研究的目的是根据即时和延迟加载模型比较植入物倾角和加载时间对植入物周围骨中应力分布的影响。构造了四个不同后植入物倾斜角度(0度,15度,30度,45度)的3D FEA模型。在多矢量方向上的150 N静态载荷被单侧施加到悬臂区域。在骨整合之前和之后评估植入物周围骨中的应力分布。骨骼的主拉伸应力(sigma(max)),平均主拉伸应力(sigma(max)),主压缩应力(sigma(min))和平均主压缩应力(sigma(min))和接触时的微动计算出骨骼与植入物之间的界面。在所有模型中,峰值主应力出现在左倾斜植入物周围的骨骼中。对于立即加载模型和延迟加载模型,在0度模型中均观察到最高的sigma(max)和sigma(min)。并且0度和15度模型显示出更高的sigma(max)和sigma(min)值。 0度模型显示最大的微动。在30度和45度模型中,观察到的应力分布比在0度和15度模型中更好。

著录项

  • 来源
  • 作者单位

    Chongqing Med Univ, Coll Stomatol, Chongqing, Peoples R China|Chongqing Municipal Key Lab Oral Biomed Engn High, Chongqing, Peoples R China;

    Chongqing Med Univ, Coll Stomatol, Chongqing, Peoples R China|Chongqing Municipal Key Lab Oral Biomed Engn High, Chongqing, Peoples R China;

    Chongqing Med Univ, Coll Stomatol, Chongqing, Peoples R China|Chongqing Municipal Key Lab Oral Biomed Engn High, Chongqing, Peoples R China;

    Chongqing Med Univ, Coll Stomatol, Chongqing, Peoples R China|Chongqing Key Lab Oral Dis & Biomed Sci, Chongqing, Peoples R China;

    Chongqing Med Univ, Coll Stomatol, Chongqing, Peoples R China|Chongqing Key Lab Oral Dis & Biomed Sci, Chongqing, Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    "All-on-Four" concept; immediate loading; tilted implant; finite element analysis;

    机译:“全力以赴”概念;立即加载;倾斜植入物;有限元分析;