首页> 外文期刊>Composite Structures >Effects of ply thickness deviation and ply angle misalignment on the surface accuracy of CFRP laminates
【24h】

Effects of ply thickness deviation and ply angle misalignment on the surface accuracy of CFRP laminates

机译:帘布层厚度偏差和层角度未对流对CFRP层压板表面精度的影响

获取原文
获取原文并翻译 | 示例
           

摘要

This study examines two factors that affect the surface accuracy of symmetric carbon-fibre-reinforced plastic (CFRP) laminates: ply angle misalignment and ply thickness deviation. First, based on classic laminate theory, theoretical expressions for the effects of these factors are deduced. Then, COMSOL (FEM software) is used to analyse the relationship between these factors and the surface accuracy, and Zernike polynomials are used to fit the surface deformation of the CFRP laminates. It proves that ply angle misalignment and ply thickness deviation can cause astigmatic and power aberrations. Based on the integral constraint method in the form of Lagrangian multipliers, the rigid body displacement problem of the free thermal expansion simulation of CFRP laminates has been solved. Finally, three groups of experimental tests show that ply thickness deviation does occur. A ZYGO interferometer is used to observe the surface accuracy of the laminates, and it shows that astigmatism is the dominant aberration.
机译:本研究检查了影响对称碳纤维增强塑料(CFRP)层压板的表面精度的两个因素:帘布层角度未对准和帘布层厚度偏差。首先,基于经典层压理论,推导了这些因素影响的理论表达。然后,COMSOL(FEM软件)用于分析这些因素和表面精度之间的关系,并且Zernike多项式用于符合CFRP层压板的表面变形。它证明了帘布层角度未对准和帘布层厚度偏差可引起散光和功率像差。基于拉格朗日乘法器形式的积分约束方法,解决了CFRP层压板的自由热膨胀模拟的刚性体位移问题。最后,三组实验测试表明,发生帘布层厚度偏差。 Zygo干涉仪用于观察层压板的表面精度,表明散光是显性像差。

著录项

  • 来源
    《Composite Structures》 |2021年第8期|114073.1-114073.11|共11页
  • 作者单位

    Chinese Acad Sci Changchun Inst Opt Fine Mech & Phys Changchun 130033 Peoples R China|Univ Chinese Acad Sci Beijing 100049 Peoples R China;

    Chinese Acad Sci Changchun Inst Opt Fine Mech & Phys Changchun 130033 Peoples R China;

    Chinese Acad Sci Changchun Inst Opt Fine Mech & Phys Changchun 130033 Peoples R China;

    Jilin Univ Changchun 130012 Peoples R China;

    Chinese Acad Sci Changchun Inst Opt Fine Mech & Phys Changchun 130033 Peoples R China|Univ Chinese Acad Sci Beijing 100049 Peoples R China;

    Chinese Acad Sci Changchun Inst Opt Fine Mech & Phys Changchun 130033 Peoples R China|Univ Chinese Acad Sci Beijing 100049 Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Ply thickness deviation; Ply angle misalignment; CFRP; Surface accuracy; Zernike polynomial;

    机译:帘布层厚度偏差;帘布层角度未对准;CFRP;表面精度;Zernike多项式;