An experimental study of the effects of hot-wet conditions on the load carrying capacity of pultruded GRP (glass reinforced plastic) single-bolt tension joints has been carried out. The bolted joints were failed in tension after being immersed in water at three temperatures for two periods of time. Two joint geometries, defined in terms of end distance and width to bolt diameter, were tested with the pultrusion and tension axes coincident. The reductions in the load capacities of the joints due to the hot-wet conditions were quantified and shown to be very large. For example, it was found that more than 60% of the load carrying capacity of a single-bolt tension joint was lost after being immersed in water for 6.5 weeks at 60℃. This temperature is lower than the manufacturer's recommended maximum service temperature for this type of pultruded GRP material.
机译:进行了热湿条件对拉挤玻璃纤维增​​强塑料(GRP)单螺栓拉伸接头的承载能力影响的实验研究。螺栓接头在三种温度下浸入水中两次后,无法拉伸。在拉挤轴和张力轴重合的情况下测试了两个根据端部距离和宽度与螺栓直径的关系定义的接头几何形状。量化了由于热湿条件导致的接头承载能力的降低,并且显示出非常大的降低。例如,发现在60℃下将单螺栓拉伸接头浸入水中6.5周后会损失超过60%的承载能力。该温度低于制造商推荐的这种拉挤GRP材料的最高使用温度。