首页> 外文期刊>Composite Structures >Analysis of a glass fibre reinforced polyurethane composite repair system for corroded pipelines at elevated temperatures
【24h】

Analysis of a glass fibre reinforced polyurethane composite repair system for corroded pipelines at elevated temperatures

机译:高温下腐蚀管道的玻璃纤维增​​强聚氨酯复合材料修复系统分析

获取原文
获取原文并翻译 | 示例

摘要

The present paper is concerned with the analysis of glass fibre reinforced polyurethane repair systems for metallic pipelines with localised corrosion damage that impair the serviceability. The main motivation for the study presented in this paper is the rehabilitation of corroded pipelines conveying produced water in offshore oil platforms. Although the operating pressure of these pipelines is not very high, the water temperature is between 60 and 90℃, which can be a major shortcoming for the use of polymeric material as repair systems. Tensile tests were performed to analyse the temperature dependence of a polyurethane pre-impregnated, bi-directional E-glass fibre composite. Burst tests were carried out to evaluate the performance of composite reinforcements applied to defects machined in pipeline test specimens. Preliminary ideas for a methodology to estimate the failure pressure of a reinforced specimen with arbitrary localised corrosion damage are presented.
机译:本文涉及对金属管道的玻璃纤维增​​强聚氨酯修补系统的分析,该系统具有局部腐蚀损害,从而削弱了其使用寿命。本文提出的研究的主要动机是修复在海上石油平台中输送产出水的腐蚀管道。尽管这些管道的工作压力不是很高,但水温在60到90℃之间,这可能是使用聚合物材料作为修复系统的主要缺点。进行拉伸测试以分析聚氨酯预浸渍的双向E玻璃纤维复合材料的温度依赖性。进行了爆破测试,以评估应用于管道测试样品中加工的缺陷的复合增强材料的性能。提出了一种方法的初步思想,该方法用于估计具有任意局部腐蚀破坏的钢筋试样的破坏压力。

著录项

  • 来源
    《Composite Structures》 |2014年第8期|117-123|共7页
  • 作者单位

    Laboratory of Theoretical and Applied Mechanics, Graduate Program in Mechanical Engineering, Universidade Federal Fluminense, Rua Passo da Patria 156, 24210-240 Niteroi, RJ, Brazil;

    Laboratory of Theoretical and Applied Mechanics, Graduate Program in Mechanical Engineering, Universidade Federal Fluminense, Rua Passo da Patria 156, 24210-240 Niteroi, RJ, Brazil;

    Laboratory of Theoretical and Applied Mechanics, Graduate Program in Mechanical Engineering, Universidade Federal Fluminense, Rua Passo da Patria 156, 24210-240 Niteroi, RJ, Brazil;

    Laboratory of Theoretical and Applied Mechanics, Graduate Program in Mechanical Engineering, Universidade Federal Fluminense, Rua Passo da Patria 156, 24210-240 Niteroi, RJ, Brazil;

    Laboratory of Theoretical and Applied Mechanics, Graduate Program in Mechanical Engineering, Universidade Federal Fluminense, Rua Passo da Patria 156, 24210-240 Niteroi, RJ, Brazil;

    Research and Development Center - CENPES, Petroleo Brasileiro SA. - PETROBRAS, Av. Hordcio de Macedo 950,21941-915, Cidade Universitaria, llha do Fundao, Rio de Janeiro, RJ, Brazil;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Glass fibre reinforced polyurethane; Tensile tests; Temperature; Pipeline repair systems;

    机译:玻璃纤维增​​强聚氨酯;拉伸试验;温度;管道维修系统;