首页> 外文期刊>Composite Structures >Seismic mobile shaker testing of full-scale RC building frames with high-strength NSM-FRP hybrid retrofit system
【24h】

Seismic mobile shaker testing of full-scale RC building frames with high-strength NSM-FRP hybrid retrofit system

机译:使用高强度NSM-FRP混合改造系统对大型RC建筑框架进行地震移动台振动测试

获取原文
获取原文并翻译 | 示例
       

摘要

Past seismic events have led to the premature failure of many existing seismically-vulnerable reinforced concrete building frames due to their inadequate column details. To ensure the ductile behavior of the non-ductile building frames, a hybrid retrofit system combining high-strength near surface mounted bars (flexural retrofit) with carbon fiber reinforced polymer sheets (shear retrofit) can be installed to the seismically-vulnerable columns. This study presents the experimental dynamic assessment of the non-ductile building frames retrofitted with the hybrid system. To prevent the column shear failure due to the flexural strengthening, a two-stage design procedure for the hybrid retrofit system was proposed. The full-scale dynamic testing was performed on the retrofitted test frame to realistically measure dynamic responses and quantify the retrofit effects. The hybrid retrofit system reduced the peak inter-story drift of the first-story columns by about 25% and their hinge rotation by approximately 76%. Additionally, the retrofit system can uniformly distribute the damage or drift over the entire structure, i.e. mitigation of soft-story mechanism.
机译:过去的地震事件由于缺乏足够的立柱细节,导致许多现有的易受地震破坏的钢筋混凝土建筑框架过早失效。为了确保非延展性建筑框架的延展性,可以在高抗震柱上安装将高强度近表面安装钢筋(抗弯改造)与碳纤维增强聚合物板(抗剪改造)相结合的混合改造系统。这项研究提出了用混合动力系统改造的非延性建筑框架的实验动态评估。为了防止由于抗弯加固而引起的柱剪切破坏,提出了混合改造系统的两阶段设计程序。在改装的测试框架上进行了全面的动态测试,以实际测量动态响应并量化改装效果。混合改造系统将第一层色谱柱的层间峰值漂移降低了约25%,并将其铰链旋转降低了约76%。另外,改型系统可以将损坏或漂移均匀地分布在整个结构上,即减轻软故事机制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号