首页> 外文期刊>Communications in Numerical Methods in Engineering >The biomechanical effects of stapes replacement by prostheses on the tympano-ossicular chain
【24h】

The biomechanical effects of stapes replacement by prostheses on the tympano-ossicular chain

机译:假体置换replacement骨对鼓膜听骨链的生物力学作用

获取原文
获取原文并翻译 | 示例

摘要

Hearing is a sequence of processes in which the ear translates sound waves into electrical signals, which are then sent to the brain where they are interpreted as sound. The ossicular chain of the middle ear is formed by three ossicles (malleus, incus, and stapes), of which the last and smallest, the stapes, vibrates, thus communicating with the inner ear through the stapes footplate. When abnormal bone formation immobilizes the stapes (otosclerosis), the passage of sound does not correctly occur and hearing can be compromised. In most cases, surgery is an option for its treatment. The stapes is totally or partially replaced by a prosthesis (stapedectomy or stapedotomy, respectively) allowing the passage of sound to the inner ear. This work presents a study on the behavior of different stapes prostheses, considering their biomechanical characteristics. The stapes was replaced by different prostheses, made of dissimilar materials: stainless steel, teflon, and titanium. The umbo and stapes footplate displacements for the models with these prostheses were obtained and compared with the displacements obtained with the model representative of the normal ear. In the models with prostheses, the displacements are found in the hole where the prosthesis is attached.
机译:听力是一系列过程,在此过程中,耳朵将声波转换为电信号,然后将其发送到大脑,在此将它们解释为声音。中耳的听骨链由三个小骨(马柳,砧骨和骨)形成,其中最后一个和最小的,骨振动,从而通过the骨足板与内耳连通。当异常的骨形成固定the骨(耳硬化症)时,声音不会正确通过,听力可能会受到损害。在大多数情况下,手术是治疗的一种选择。骨全部或部分被假体(分别为sta骨切除术或骨切开术)替代,从而允许声音传递至内耳。这项工作考虑到它们的生物力学特性,对不同的骨假体的行为进行了研究。 sta骨由不同的假体代替,这些假体由不同的材料制成:不锈钢,聚四氟乙烯和钛。获得了具有这些假体的模型的腰部和骨足板位移,并将其与用代表正常耳朵的模型获得的位移进行了比较。在带有假体的模型中,在附着假体的孔中发现了位移。

著录项

  • 来源
    《Communications in Numerical Methods in Engineering》 |2014年第12期|1409-1420|共12页
  • 作者单位

    IDMEC, Faculdade de Engenharia da Universidade do Porto, Porto, Portugal,Clinica ORL-Eurico Almeida, Porto, Portugal,Widex, ESTSP, Portugal;

    IDMEC, Faculdade de Engenharia da Universidade do Porto, Porto, Portugal;

    IDMEC, Faculdade de Engenharia da Universidade do Porto, Porto, Portugal;

    IDMEC, Faculdade de Engenharia da Universidade do Porto, Porto, Portugal;

    IDMEC, Faculdade de Engenharia da Universidade do Porto, Porto, Portugal;

    Clinica ORL-Eurico Almeida, Porto, Portugal;

    IDMEC, Faculdade de Engenharia da Universidade do Porto, Porto, Portugal,Renato Natal Jorge, Depto de Engenharia Mecanica, Faculdade de Engenharia da Universidade do Porto, Porto, Portugal;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    biomechanics; stapes; prostheses; FEM;

    机译:生物力学sta骨假肢;有限元法;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号