Problem Range Evaluation of the Hematology Analyzers Abbott CELL DYN 3500, Coulter STKS, Sysmex SE-9000 and Technicon H~*3: Analysis of Leukopenic and Thrombopenic Samples, WBC Differentials and Flagging Performance

机译:血液分析仪Abbott CELL DYN 3500,Coulter STKS,Sysmex SE-9000和Technicon H〜* 3的问题范围评估:白细胞和血栓样本,WBC差异和标记性能的分析

获取原文
获取原文并翻译 | 示例

摘要

In der vorliegenden Studie wurde eine Evaluierung verschiedener Hämatologiegeräte (Abbott CELL DYN 3500, Coulter STKS, Sysmex SE-9000 and Technicon H~*3) durchgeführt. Die Schwerpunkte lagen in der Messung leukopenischer ( < 2 x 10~9/L) und thrombo-penischer Proben ( < 100 x 10~9/L), im Vergleich automatischer und manueller Verfahren zur Erstellung von Differentialblutbildern sowie in der Analyse von Warnhinweisen bei morphologisch unauffälligen sowie auffälligen Proben (mit vorwiegend niedriger Anzahl pathologischer Zellen). Unsere Experimente zeigten, daß der CELL DYN 3500 und der SE-9000 Leukozyten auch unterhalb der Linearitätsgrenze von 0.1 x 10~9/L exakt messen konnten. Darüberhinaus war die Handhabung beider Geräte am einfachsten. Die Messung thrombopenischer Proben ergab für alle Analysengeräte vergleichbare Werte, die gut mit den Kammerzählungen korrelierten. Bei diesen Proben müssen jedoch immer Störfaktoren wie Thrombozytenaggregate ausgeschlossen werden. Der Vergleich von Differentialblutbildern, die sowohl morphologisch unauffällig waren als auch von den Geräten nicht gewarnt wurden, zeigt bei allen Automaten mit Ausnahme der Monozyten und der basophilen Granulozyten eine gute Korrelation zwischen den Gerätewerten und der Handdifferenzierung. Bei der Analyse der Warnhinweise morphologisch unauffälliger sowie pathologischer Proben lieferte der STKS die niedrigste Anzahl falsch negativer Ergebnisse, gefolgt vom SE-9000.%We performed a problem range evaluation of four fully automated hematology analyzers (Abbott CELL-DYN $500, Coulter STKS, Sysmex SE-9000 and Technicon H~*3). The protocol included the evaluation of complete white blood counts in leukopenic samples ( < 2 x 10~9/L), thrombocyte counts in samples with thrombocytes < 100 x 10~9/L and WBC differentials together with flagging analysis of morphologically normal and pathological blood samples (with predominantly low numbers of pathological cells). Our data showed that CELL DYN 3500 and SE-9000 accurately counted leukocytes in leukopenic blood samples even below the lower linearity range (0.1 x 10~9/L) and were easier to handle than the other analyzers tested. The results of thrombocyte counts in thrombopenic blood samples were comparable between all analyzers tested and correlated well with the manual count. However, caution is needed to exclude platelet aggregates in thrombopenic blood samples. Comparing WBC differentials of morphologically normal (and not flagged) samples between the analyzers' results showed comparable, good correlations for lymphocytes, granulocytes and eosinophils and poor correlations for basophils and monocytes for all analyzers. Truth table analysis of WBC differentials of morphologically normal as well as pathological samples revealed that the STKS gave the lowest number of false negative results followed by SE-9000.
机译:在本研究中,对各种血液学设备(Abbott CELL DYN 3500,Coulter STKS,Sysmex SE-9000和Technicon H〜* 3)进行了评估。重点是测量白细胞减少症(<2 x 10〜9 / L)和血栓性样品(<100 x 10〜9 / L),比较自动和手动程序以创建差异血细胞计数并分析警告形态学上不明显的样品以及明显的样品(病理细胞数量少)。我们的实验表明,CELL DYN 3500和SE-9000可以测量精确低于线性极限0.1 x 10〜9 / L的白细胞。另外,这两种设备的处理都是最简单的。血栓形成样本的测量为所有分析仪提供了可比较的值,与房间计数很好相关。但是,在这些样品中必须始终排除干扰因素,例如血小板聚集体。差异血细胞计数的比较在形态上不明显,并且没有被设备警告,显示了设备值与除单核细胞和嗜碱性粒细胞外的所有机器中的手分化之间的良好相关性。分析形态正常和病理样本的警告时,STKS给出的假阴性结果最少,其次是SE-9000。%我们对四个全自动血液分析仪(Abbott CELL-DYN $ 500,Coulter STKS,Sysmex, SE-9000和Technicon H〜* 3)。该方案包括评估白细胞减少症样本中的全白血球计数(<2 x 10〜9 / L),血小板<100 x 10〜9 / L样本中的血小板计数和WBC差异以及形态正常和病理学的标记分析血液样本(病理细胞数量少)。我们的数据表明,CELL DYN 3500和SE-9000甚至可以在低于较低线性范围(0.1 x 10〜9 / L)的情况下准确计数白细胞减少症血液样本中的白细胞,并且比其他测试分析仪更易于操作。在所有测试的分析仪中,血栓形成血样中的血小板计数结果是可比的,并且与手动计数的相关性很好。但是,需要注意排除血小板聚集在血栓形成性血液样本中。比较分析仪结果之间形态正常(且未标记)样品的WBC差异显示,所有分析仪的淋巴细胞,粒细胞和嗜酸性粒细胞可比,良好的相关性,而嗜碱性粒细胞和单核细胞的相关性较差。形态正常和病理样本的WBC差异的真值表分析显示,STKS产生的假阴性结果最少,其次是SE-9000。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号