首页> 外文期刊>Circuits and systems >Appropriate Placement of Fault Current Limiting Reactors in Different HV Substation Arrangements
【24h】

Appropriate Placement of Fault Current Limiting Reactors in Different HV Substation Arrangements

机译:在不同的高压变电站布置中适当放置故障限流电抗器

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Short circuit currents of power systems are growing with an increasing rate, due to the fast development of generation and transmission systems. Current Limiting Reactor is one of the effective short circuit current limiting devices. This technique is known to be more practical than other available approaches. In this paper, proper application of CLR to HV substations is proposed, based on a comprehensive short circuit analysis of 4 well-known substation bus bar arrangements. Eventually, appropriate place and number of CLRs is recommended for each bus bar arrangement.