首页> 外文期刊>Chemosphere >Atmospheric pressure ionization for gas chromatography-high resolution mass spectrometry determination of polychlorinated naphthalenes in marine sediments
【24h】

Atmospheric pressure ionization for gas chromatography-high resolution mass spectrometry determination of polychlorinated naphthalenes in marine sediments

机译:气相色谱 - 气相色谱 - 高分辨率质谱法测定海洋沉积物中多氯萘萘的高分辨率

获取原文
获取原文并翻译 | 示例
           

摘要

In this work, the performance of the atmospheric pressure chemical ionization (APCI) and photoionization (APPI) was assessed to develop a new selective and sensitive gas chromatography-high resolution mass spectrometry (GC-HRMS) method for the determination of polychlorinated naphthalenes (PCNs) in sediment samples. The capability of both APCI and APPI sources for the ionization of PCNs was investigated, showing the formation of the molecular ion and the [M-Cl+O](-) ion in positive and negative ion modes, respectively. Positive ion APCI provided high responses using high corona ion current, while the use of high vapour pressure dopant-solvents, such as toluene in positive mode and diethyl ether in the negative mode, was required to achieve high ionization efficiencies in APPI. The performance of the two API sources in the PCN determination by GC-HRMS were compared and the best results were achieved using the GC-APPI(+)-HRMS (Orbitrap) system. The GC-APPI(+)-HRMS (Orbitrap) method was applied to the characterization of Halowax mixtures and the analysis of marine sediments collected near to the coastal area of Barcelona (NE, Spain), demonstrating a great detection capability with low method limits of detection (0.2-1.6 pg g(-1) dry weight), good precision (RSD 15%) and trueness (relative error 13%). Total PCN concentrations ranged from 0.35 to 5.0 ng g(-1) dry weight and the presence of related compounds, such as polychlorinated biphenyls (PCBs), was also detected by combining positive and negative ion modes, providing complementary information to better monitor of all PCN congener groups. The results presented here show the feasibility of the GC-APPI-HRMS method for the suitable determination of PCNs. (C) 2020 Elsevier Ltd. All rights reserved.
机译:在这项工作中,评估了大气压化学电离(APCI)和光离子化(APPI)的性能,以开发一种新的选择性和敏感的气相色谱 - 高分辨率质谱(GC-HRMS)方法,用于测定聚氯萘甲苯(PCNS )在沉积物样本中。研究了APCI和APPI源的能力,分别研究了PCN的电离,显示分子离子和负离子模式中的分子离子和[M-Cl + O]( - )离子的形成。正离子APCI使用高电晕离子电流提供高响应,而在阴性模式下使用高蒸气压掺杂剂 - 溶剂,例如甲苯,在负模式下,在APPI中实现高电离效率。比较GC-HRMS的PCN测定中的两个API源的性能,并使用GC-APPI(+) - HRMS(orbitrap)系统实现了最佳结果。将GC-APPI(+) - HRMS(Orbitrap)方法应用于Halowax混合物的表征以及在巴塞罗那(NE,Spain)沿海地区附近收集的海洋沉积物分析,展示了低法律限制的良好检测能力检测(0.2-1.6克(-1)干重),精度良好(RSD <15%)和真实(相对误差<13%)。通过组合正和负离子模式,还检测到总PCN浓度范围为0.35至5.0ng(-1)干重和存在相关化合物,例如多氯联苯(PCB),提供互补信息以更好地监测所有的信息PCN Congener组。此处提出的结果显示了GC-APPI-HRMS方法的可行性,用于适当确定PCN。 (c)2020 elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号