首页> 外文期刊>Chemosphere >Retention time profiling of all 136 tetra- through octa- chlorinated dibenzo-p-dioxins and dibenzofurans on a variety of Si-Arylene gas chromatographic stationary phases
【24h】

Retention time profiling of all 136 tetra- through octa- chlorinated dibenzo-p-dioxins and dibenzofurans on a variety of Si-Arylene gas chromatographic stationary phases

机译:在各种Si-亚芳基气相色谱固定相上所有136种四氯至八氯代二苯并对二恶英和二苯并呋喃的保留时间分析

获取原文
获取原文并翻译 | 示例
       

摘要

The applicability of three different Silphenylene Silicone co-polymer (Si-Arylene) CC stationary phases (J&W Scientific DB-5ms, Varian VF-5ms, and VF-Xms) has been evaluated for the separation of all 136 tetra- through the octa- chlorinated dibenzo-p-dioxins (PCDD) and chlorinated dibenzofurans (PCDF) from closely eluting isomers using gas chromatography/high resolution mass spectrometry (GC/HRMS). Their relative performance data are compared to the "conventional" 5% diphenyl 95% dimethylpolysilox-ane GC column (Supelco Equity-5) and to each other based on absolute retention times, visualized mass chromatograms, and the separation of 2,3.7,8-substituted isomers. VF-Xms GC column was able to demonstrate a better performance towards separation of 2,3,7,8-substituted PCDD/PCDF compared to other Si-Arylene GC columns tested, where only 2,3,4,7,8-PnCDF can not be resolved from 1,2,3,6,9-PnCDF and 2,3,4,6,7,8-/1,2,3,6,8,9-HxCDF and 1,2,3,7,8,9-/1,2,3,4,8,9-HxCDF can be at least partially resolved. These data suggest that the development of a single GC column for the separation of all 17 2,3,7,8-substituted dioxins and furans is feasible, which therefore could be used as a standard tool for the PCDD/PCDF methods globally including USEPA methods 1613b, 8290A, 8280B, European Standard Method EN 1948, Canadian methods DFPCB-E3418, EPS l/RM/19, Japanese methods JIS K0311 and JIS K0312. Having one specific GC column to separate all 2,3,7,8-substituted PCDD/PCDF will significantly improve the data quality, comparability by the various methods and assessment techniques while simultaneously leading to a more cost and time efficient operation.
机译:已评估了三种不同的亚甲硅烷基硅氧烷共聚物(Si-Arylene)CC固定相(J&W Scientific DB-5ms,Varian VF-5ms和VF-Xms)的适用性,可用于分离所有136-四-八烷基使用气相色谱/高分辨率质谱法(GC / HRMS)从紧密洗脱的异构体中提取氯代二苯并-对-二恶英(PCDD)和氯代二苯并呋喃(PCDF)。根据绝对保留时间,可视化的质谱图和2,3.7,8的分离度,将它们的相对性能数据与“常规” 5%联苯95%二甲基聚硅氧烷-GC柱(Supelco Equity-5)进行比较。取代的异构体。与仅测试2,3,4,7,8-PnCDF的其他Si-Arylene GC色谱柱相比,VF-Xms GC色谱柱在分离2,3,7,8-取代的PCDD / PCDF方面表现出更好的性能无法从1,2,3,6,9-PnCDF和2,3,4,6,7,8- / 1,2,3,6,8,9-HxCDF和1,2,3解析, 7,8,9- / 1,2,3,4,8,9-HxCDF可以至少部分解析。这些数据表明,开发用于分离所有17种2,3,7,8-取代的二恶英和呋喃的单一GC色谱柱是可行的,因此可以用作全球PCDD / PCDF方法(包括USEPA)的标准工具方法1613b,8290A,8280B,欧洲标准方法EN 1948,加拿大方法DFPCB-E3418,EPS l / RM / 19,日本方法JIS K0311和JIS K0312。拥有一个单独的GC色谱柱来分离所有2,3,7,8-取代的PCDD / PCDF可以通过各种方法和评估技术显着提高数据质量,可比性,同时还可以提高成本和时间效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号