...
首页> 外文期刊>Chemosphere >Confirmation of polychlorinated biphenyl (PCB) distribution in the blood and verification of simple quantitative method for PCBs based on specific congeners
【24h】

Confirmation of polychlorinated biphenyl (PCB) distribution in the blood and verification of simple quantitative method for PCBs based on specific congeners

机译:确认血液中多氯联苯(PCB)的分布并验证基于特定同源物的PCBs定量方法的简便性

获取原文
获取原文并翻译 | 示例
           

摘要

We measured the concentration of each polychlorinated biphenyl (PCB) congener in whole blood, plasma and blood cells, and investigated the distribution of PCBs in human blood using high-resolution gas chro-matography/high-resolution mass spectrometry (HRCC/HRMS). The PCB concentrations in plasma and whole blood in terms of lipid concentrations were almost equal, with a correlation coefficient of r= 0.972. In the blood, the ratio of PCBs in blood cells to those in plasma was generally about 1:9 and the congener distribution patterns in blood cells and plasma were similar. We performed verification of a simple mass screening method by obtaining information on the main PCB congeners for investigations on human accumulation and exposure. The total concentration of the seven PCB congeners (UNEP-7) proposed to the United Nations Environment Programme (UNEP) by Muir and Morita was about 50% of the total concentration of all PCB congeners, and UNEP-30 was about 80%. The seven main congeners in the blood (MCB-7) showed a value that was about 60%, and MCB-30 showed a value that was about 90%. Determinations with the main congeners in the blood showed a correlation of r= 0.990 or more between the main eight congeners (MCB-7 plus #74) and the total PCB concentration for all congeners. The results suggest that, although total PCB concentration can be effectively estimated from the main seven congeners, the main eight congeners would be preferable, and that the use of these congeners in the simple mass screening method would be effective for populations in areas uncontam-inated by PCBs.
机译:我们测量了全血,血浆和血细胞中每种多氯联苯(PCB)同类物的浓度,并使用高分辨率气相色谱/高分辨率质谱(HRCC / HRMS)研究了人血中PCBs的分布。就血脂浓度而言,血浆和全血中的PCB浓度几乎相等,相关系数r = 0.972。在血液中,血细胞中PCBs与血浆中PCBs的比例通常约为1:9,并且血细胞和血浆中同类物质的分布方式相似。我们通过获取有关主要PCB同类物的信息来进行人类聚集和暴露调查的简单质量筛选方法的验证。 Muir和Morita向联合国环境规划署(UNEP)提议的七个多氯联苯同类物(UNEP-7)的总浓度约为所有多氯联苯同类物总浓度的50%,而UNEP-30则约为80%。血液中的七个主要同类物(MCB-7)的值约为60%,MCB-30的值约为90%。对血液中主要同源物的测定表明,主要八个同源物(MCB-7加#74)与所有同类物的总PCB浓度之间的r = 0.990或更高。结果表明,虽然可以从主要的七个同类物有效地估算出总PCB浓度,但主要的八个同类物将是可取的,并且在简单的质量筛选方法中使用这些同类物对于未污染地区的人群将是有效的。通过PCB。

著录项

  • 来源
    《Chemosphere》 |2011年第1期|p.107-113|共7页
  • 作者单位

    SRL, Inc., 153 Komiya-cho, Hachioji. Tokyo 192-0031. Japan,Department of Bioenvironmental Medicine, Graduate School of Medicine, Chiba University, 1-8-1 lnohana, Chuo-ku, Chiba 260-8670, Japan;

    Center for Preventive Medical Science, Chiba University, 1-8-1 lnohana, Chuo-ku, Chiba 260-8670, Japan,Division JPD Co., Ltd., 7-98 Kita-ltami, Itami, Hyogo 664-0831,Japan;

    Department of Bioenvironmental Medicine, Graduate School of Medicine, Chiba University, 1-8-1 lnohana, Chuo-ku, Chiba 260-8670, Japan,Center for Preventive Medical Science, Chiba University, 1-8-1 lnohana, Chuo-ku, Chiba 260-8670, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    polychlorinated biphenyls; whole blood; blood cell; plasma; main congener;

    机译:多氯联苯;全血;血细胞;等离子体;主要同类;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号