首页> 外文期刊>Chemosphere >Time-integrated monitoring of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in urban and industrial wastewaters using a ceramic toximeter and the CALUX bioassay
【24h】

Time-integrated monitoring of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in urban and industrial wastewaters using a ceramic toximeter and the CALUX bioassay

机译:使用陶瓷毒物测定仪和CALUX生物分析仪对城市和工业废水中的多氯二苯并对二恶英和多氯二苯并呋喃(PCDD / Fs)进行时间集成监测

获取原文
获取原文并翻译 | 示例
           

摘要

The ceramic toximeter as a passive sampler in combination with the CALUX bioassay was utilized as a time-integrated pollution-assessment technique for dioxin-like PCDD/Fs in wastewaters. Toximeters filled with XCARB and enclosed in stainless steel cages were submerged in wastewater of Belbeis drainage-canal and EMAK paper-mill, located in Egypt, for 28 days. Two samplers were removed every week from each site. Extracts from toximeters, from bottom-sediments, and from paper-mill sludge were analyzed by the CALUX. Results showed a regular increase in the amounts of PCDD/Fs trapped by the toximeters as sampling time increased. Time-weighted average concentrations (TWA) of PCDD/Fs in the wastewaters of the drainage-canal and paper-mill were 231 (214-281) and 26 (24.1-32.6) pg-BEQ L~(-1) respectively. Compared to literature data, this means a high pollution level for the drainage-canal water, while the pollution level in the paper-mill wastewater is similar to that reported for other paper mills. The PCDD/Fs levels in the drainage-canal bottom-sediments and in the paper-mill sludge were 8.3 and 14.6 pg-BEQ g~(-1) dry-weight, at the lower end of internationally reported values in similar compartments. The sampling rate of the tested toximeters for dissolved PCDD/Fs was about 3.6 mL d~(-1). Sediment/water partitioning coefficient log K_d of PCDD/Fs in the drainage-canal and the paper-mill was 1.42 and 2.70 respectively. The organic-carbon normalized partition coefficient log K_(oc) was 4.17 and 3.19 respectively, and is lower than the reported values for other sites.
机译:陶瓷毒物测定仪作为被动采样器与CALUX生物测定相结合,被用作时间综合污染评估技术,用于处理废水中的二恶英样PCDD / Fs。将充满XCARB并封闭在不锈钢笼中的毒物计浸没在位于埃及的Belbeis排水渠和EMAK造纸厂的废水中28天。每周从每个站点中删除两个采样器。 CALUX分析了血氧仪,底泥和造纸厂污泥中的提取物。结果表明,随着采样时间的增加,被血氧仪捕获的PCDD / Fs数量有规律地增加。排水渠和造纸厂废水中PCDD / Fs的时间加权平均浓度(TWA)分别为231(214-281)和26(24.1-32.6)pg-BEQ L〜(-1)。与文献数据相比,这意味着排水渠水的污染水平很高,而造纸厂废水中的污染水平与其他造纸厂所报告的相似。排水管底部沉积物中和造纸厂污泥中的PCDD / Fs水平分别为干重的8.3和14.6 pg-BEQ g〜(-1),在国际报告的同类隔室中较低。对于溶解的PCDD / Fs,被测血氧仪的采样率约为3.6 mL d〜(-1)。排水渠和造纸厂中PCDD / Fs的泥沙/水分配系数log K_d分别为1.42和2.70。有机碳归一化分配系数log K_(oc)分别为4.17和3.19,并且低于其他站点的报告值。

著录项

  • 来源
    《Chemosphere》 |2014年第1期|27-35|共9页
  • 作者单位

    Department of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussels, Belgium;

    Department of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussels, Belgium;

    Department of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussels, Belgium;

    Department of Environmental Toxicology, University of California at Davis, Davis, CA 95616, USA;

    Department of Physics, Faculty of Science, Menofia University, Shebin Elkoum, Egypt;

    Department of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussels, Belgium;

    Department of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussels, Belgium;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Passive sampling; Ceramic toximeter; CALUX; PCDD/Fs; Wastewater monitoring; Partitioning coefficient;

    机译:被动采样;陶瓷血氧仪CALUX;PCDD / Fs;废水监测;分配系数;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号