Post-occupancy evaluations are routinely buried because clients and project teams don't want to be identified with poorly performing buildings. But the reasons for buildings' poor performance have gradually filtered through and are echoed in this report. It shows that a school with a high performing fabric uses least energy, proving that fabric first is the best approach. Over-complex environmental designs led to poor performance as staff and students don't have the time or expertise to handle complex control systems. Some of the schools fitted with PV panels were the least energy efficient of all the monitored projects.
机译:占用后评估通常被掩埋,因为客户和项目团队不希望被表现不佳的建筑物所识别。但是,建筑物性能不佳的原因已逐渐消除,并在本报告中得到了回应。它表明,具有高性能面料的学校使用的能源最少,证明了首先采用面料是最好的方法。过于复杂的环境设计导致性能不佳,因为教职员工没有时间或专业知识来处理复杂的控制系统。在所有受监视的项目中,一些装有光伏板的学校的能源效率最低。