Few studies have investigated the thermal environment of the work area hall in underground metro stations during winter. Two underground stations were chosen within Qingdao Metro Lines 2 and 3 to investigate the thermal environment in the work area hall in northern city metros in China. Air temperatures and wind velocity parameters were identified as key influencing factors and were continuously measured in the work area. The study found that the thermal environment fluctuates frequently in the work area throughout the day. Changes in temperatures and wind speeds were periodically caused by piston wind flowing from the platform level. To improve this heating situation in the work area in winter, the study proposes recycling waste heat from the power equipment rooms, using the air source but through the water cycle heat pump system. Insights from the study may help save energy and improve the thermal environment, and could be applied across metro stations in north China cities in winter.
机译:很少有研究调查冬季地下地铁站工作区大厅的热环境。在青岛地铁2号和3号线中选择了两个地下站,以研究中国北方城市地铁工作区大厅的热环境。空气温度和风速参数被确定为关键影响因素,并在工作区域中不断进行测量。研究发现,全天工作环境中的热环境频繁波动。温度和风速的变化是由平台水平的活塞风周期性引起的。为了改善冬季工作区的供热状况,该研究建议使用空气源但通过水循环热泵系统回收动力设备机房的废热。该研究的见解可能有助于节省能源并改善热环境,并且可以在冬季应用于华北城市的地铁站。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号