摘要

Experiments on different vent pipe diameters (nominal diameters of 100, 75 and 50 mm; DN100, DN75 and DN50, respectively) in a full-scale circuit vent building drainage system were conducted in a 60 -m high structure, and the wastewater discharge capacities as a function of vent pipe diameter were measured. Critical pipe pressures, water seal losses of sanitary fixtures and air flow rates were measured. The ultimate pressure values in pipes on lower floors were larger than those in pipes on higher floors using DN100 and DN75, which was opposite to the results with DN50. A positive correlation between the ultimate pressure values and floor heights, as well as between ultimate pressure values and water seal losses, was found for DN100 and DN75. The maximum discharge flow of the three systems using DN100, DN75 and DN50 vent pipes was 17.0 L/s, 14.0 L/s and 7.5 L/s, respectively. Nevertheless, in China, the maximum wastewater discharge capacity in a circuit vent system adopting a DN100 vent pipe connected to a DN100 drainage stack in tall residential buildings is 11.5 L/s according to the Code for Design of Building Water Supply and Drainage. Thus, the vent pipe diameter DN75 can fully meet the design requirements of drainage systems for high rise buildings in China. The engineering cost associated with material expenses for building drainage systems can be minimised by optimising the size of vent pipe based on required capacity rather than using a single size universally.
机译:在60米高的结构中,对全尺寸回路通风建筑排水系统中的不同通风管直径(标称直径分别为100、75和50 mm; DN100,DN75和DN50)进行了实验,废水排放量测量作为排气管直径的函数。测量了管道的临界压力,卫生设备的水封损耗和空气流速。使用DN100和DN75的较低楼层的管道的最终压力值大于使用较高楼层的管道的最终压力值,与DN50的结果相反。对于DN100和DN75,发现极限压力值与地板高度之间以及极限压力值与水封损耗之间存在正相关。使用DN100,DN75和DN50排气管的三个系统的最大排放流量分别为17.0 L / s,14.0 L / s和7.5 L / s。但是,在中国,根据《建筑物给排水设计规范》,在高层住宅中采用DN100排气管连接到DN100排水管的循环排气系统的最大废水排放量为11.5 L / s。因此,排气管直径DN75可以完全满足中国高层建筑排水系统的设计要求。通过根据要求的容量而不是普遍使用单个尺寸来优化通风管的尺寸,可以使与建筑物排水系统的材料费用相关的工程成本最小化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号