首页> 外文期刊>Building and Environment >Impacts of some building passive design parameters on heating demand for a cold region
【24h】

Impacts of some building passive design parameters on heating demand for a cold region

机译:某些建筑被动设计参数对寒冷地区供热需求的影响

获取原文
获取原文并翻译 | 示例
       

摘要

In this study, the impact of passive design parameters such as building shape and orientation position on heating demand has been theoretically investigated. Therefore, a transient heat transfer problem in the building envelope with insulation and without insulation is solved by using the finite difference method. The considered buildings are placed on the ground with the azimuth angles from 0° to 90°. The heat loss per unit area of the buildings is computed by hour-hour and the yearly energy consumption of the buildings is also determined in the simulation model. The climatic data of Elazig (38.4°N), a city located in a cold region of Turkey, are considered for the analysis. It is shown that buildings with a square shape have more advantages, and the most suitable orientation angles are 0° and 80° for buildings having shape factors (the ratio of building length to building depth ) 2/1 and 1/2, respectively.
机译:在这项研究中,从理论上研究了被动设计参数(例如建筑物的形状和方向位置)对供热需求的影响。因此,通过使用有限差分法解决了具有绝热层和不具有绝热层的建筑物围护结构中的瞬态传热问题。所考虑的建筑物以0°至90°的方位角放置在地面上。建筑物单位面积的热损失按小时/小时计算,建筑物的年能耗也由仿真模型确定。分析时考虑了位于土耳其寒冷地区的Elazig(38.4°N)的气候数据。结果表明,具有正方形形状的建筑物具有更多的优势,对于形状因子(建筑物长度与建筑物深度之比)分别为2/1和1/2的建筑物,最合适的定向角为0°和80°。