首页> 外文期刊>Building and Environment >On-site measurement of indoor environment quality in a Chinese healthcare facility with a semi-closed hospital street
【24h】

On-site measurement of indoor environment quality in a Chinese healthcare facility with a semi-closed hospital street

机译:现场测量中国医疗保健设施的室内环境质量和半封闭式医院街道

获取原文
获取原文并翻译 | 示例
       

摘要

With hospitals in megacities becoming larger, the hospital-street layout has an increasingly larger impact on the efficiency and stability of a hospital. In this study, the indoor-environment quality of a semi-closed hospital street and the adjacent outpatient waiting areas were investigated using objective on-site measurements and subjective questionnaire-based surveys. The results revealed that the hospital street had an over-heated and over-humid environment, with a humidity ratio of 17.7-18.6 g/kg. Consequently, the occupant-dissatisfaction rate in terms of the thermal environment exceeded 50%. The blending of air from the hospital street with that from the outpatient waiting areas led to an indoor air temperature of 27-29 degrees C in the latter, which exceeds the standard threshold of 26 degrees C. The indoor air quality (in terms of CO2, total volatile organic compounds (TVOC), and PM2.5 concentration) of the hospital street was good, ensuring compliance with existing Chinese standards. However, spot glare through the transparent ethylene-tetra-fluoro-ethylene (ETFE) membrane roof and uneven illumination in the hospital street caused visual discomfort. Vibration of the ETFE membrane roof during rainfall led to noise levels of 79.5 dB(A) in the hospital street and 70 dB(A) in the outpatient waiting rooms, severely reducing acoustic comfort and resulting in an occupant-dissatisfaction rate of 60%. Thus, this study provides data, both objective and subjective, of the indoor-environment quality in both hospital streets and outpatient waiting areas.
机译:随着Megacities的医院变得更大,医院街道布局对医院的效率和稳定性产生了越来越大的影响。在这项研究中,使用客观的现场测量和基于主观调查问卷调查,调查了半封闭医院街道和邻近门诊等待区域的室内环境质量。结果表明,医院街有过热且过度潮湿的环境,湿度率为17.7-18.6克/千克。因此,在热环境方面的乘员 - 不满率超过50%。从医院街道的空气中的融合从门诊等候区域导致后者的室内空气温度为27-29摄氏度,超过26摄氏度的标准阈值。室内空气质量(在二氧化碳方面,医院街道的总挥发性有机化合物(TVOC)和PM2.5浓度)良好,确保符合现有的中国标准。然而,斑点眩光通过透明乙烯 - 四氟乙烯(ETFE)膜屋顶和医院街道的不均匀照明导致视觉不适。降雨期间ETFE膜屋顶的振动导致医院街道79.5 dB(a)的噪音水平,在门诊候诊室中的70 dB(a),严重降低声学舒适度,导致乘员不满60%。因此,本研究提供了医院街道和门诊等候区的室内环境质量的数据,目标和主观。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号