In this technical note we describe a real-time visual feedback device for use during radiotherapy treatment. The device displays a patient's live pose and position, relative to a reference, to them, helping them to control and maintain their motion. The device uses an optical sensor system developed at The Christie NHS Foundation Trust that is capable of real-time performance of up to 24 unique wide-area body surface measurements per second. The feedback device has integrated audio and three intuitive visualisation modes designed to show different levels of detail with varying degrees of complexity: a '2D traffic-light display', '3D flexing lamina display' and '3D colour-mapped surface display'. The performance characteristics of the system were measured, with the frame rate, throughput and latency of the feedback device being 22.4 fps, 47.0 Mbps, 109.8 ms, and 13.7 fps, 86.4 Mbps, 119.1 ms for single and three-channel modes respectively. We additionally present a novel fast method for calculating the vertical displacement map of two 3D surfaces suitable for live, real time display and evaluate its precision with respect to other methodologies.
机译:在本技术说明中,我们描述了在放射治疗期间使用的实时视觉反馈设备。该设备向患者显示患者相对于参考的实时姿势和位置,从而帮助他们控制和维持其运动。该设备使用由Christie NHS Foundation Trust开发的光学传感器系统,该系统每秒能够实时执行多达24次独特的广域体表测量。该反馈设备具有集成的音频和三种直观的可视化模式,旨在以不同的复杂程度显示不同级别的细节:“ 2D红绿灯显示”,“ 3D柔性薄片显示”和“ 3D色彩映射的表面显示”。测量了系统的性能特征,对于单通道和三通道模式,反馈设备的帧速率,吞吐量和延迟分别为22.4 fps,47.0 Mbps,109.8 ms和13.7 fps,86.4 Mbps,119.1 ms。我们还提出了一种新颖的快速方法,用于计算两个3D曲面的垂直位移图,适用于实时实时显示并相对于其他方法评估其精度。

著录项

  • 来源
    《Biomedical signal processing and control》 |2013年第6期|596-602|共7页
  • 作者单位

    Developing Technologies, Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK;

    Developing Technologies, Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK,Faculty of Medical and Human Sciences, Manchester Academic Health Sciences Centre, University of Manchester, Manchester, UK;

    Developing Technologies, Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK;

    Developing Technologies, Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK,Faculty of Medical and Human Sciences, Manchester Academic Health Sciences Centre, University of Manchester, Manchester, UK;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Radiotherapy; Optical metrology; Visualisation; Motion management;

    机译:放射治疗;光学计量;可视化;运动管理;